Comparing Manual and Automatic Artifact Detection in Sleep <scp>EEG</scp> Recordings

Sleep electroencephalogram (EEG) recordings can be contaminated by artifacts. Visual and automatic methods have been developed to mark such erroneous segments of EEG data. Here, we systematically explored the effect of artifacts on the sleep EEG power spectrum density (PSD), and we compared gold-standard visual detections to a simple automatic detector using Hjorth parameters to identify artifacts. We found that most distortions in the all-night average PSD occur because of a small minority of highly anomalous artifacts, which mainly affect the beta and gamma frequency ranges and NREM delta. Visual and automatic detections only showed moderate agreement in which data segments are artifactual. However, the resulting all-night average PSD is highly similar across all methods, and PSDs calculated with all methods successfully recover the known correlations of PSD with age and sex. No parameter settings of the automatic detector clearly outperformed others. Additionally, we showed that accurate average PSD estimates can be recovered from just a fraction of available data epochs. Our results suggest that artifacts represent a minor and easily solvable problem in sleep EEG recordings. Most visually identified artifacts do not seriously distort estimates of mid-frequency activity in the sleep EEG spectrum, and distortions to low and high frequencies can be eliminated using a simple automatic detection method nearly as well as with visual detections. These findings show that the visual inspection of EEG data is not necessary to eliminate the effects of artifacts, which is encouraging for the expected performance of automatic preprocessing in large sleep EEG databases.

Authors

Institutions

Publication Details

Journal
Psychophysiology
Published
2025-02-01
DOI
https://doi.org/10.1111/psyp.70016
Citations
1
Primary Topic
Sleep and Wakefulness Research
Type
article
Field-Weighted Citation Impact
1.43

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparing Manual and Automatic Artifact Detection in Sleep EEG Recordings

Péter P. Ujma, Martin Dresler, Róbert Bódizs
1 citations
Psychophysiology
Sleep and Wakefulness Research
1.43
article

Comparing Manual and Automatic Artifact Detection in Sleep EEG Recordings

Péter P. Ujma, Martin Dresler, Róbert Bódizs
article en
1 citations

Abstract

Sleep electroencephalogram (EEG) recordings can be contaminated by artifacts. Visual and automatic methods have been developed to mark such erroneous segments of EEG data. Here, we systematically explored the effect of artifacts on the sleep EEG power spectrum density (PSD), and we compared gold-standard visual detections to a simple automatic detector using Hjorth parameters to identify artifacts. We found that most distortions in the all-night average PSD occur because of a small minority of highly anomalous artifacts, which mainly affect the beta and gamma frequency ranges and NREM delta. Visual and automatic detections only showed moderate agreement in which data segments are artifactual. However, the resulting all-night average PSD is highly similar across all methods, and PSDs calculated with all methods successfully recover the known correlations of PSD with age and sex. No parameter settings of the automatic detector clearly outperformed others. Additionally, we showed that accurate average PSD estimates can be recovered from just a fraction of available data epochs. Our results suggest that artifacts represent a minor and easily solvable problem in sleep EEG recordings. Most visually identified artifacts do not seriously distort estimates of mid-frequency activity in the sleep EEG spectrum, and distortions to low and high frequencies can be eliminated using a simple automatic detection method nearly as well as with visual detections. These findings show that the visual inspection of EEG data is not necessary to eliminate the effects of artifacts, which is encouraging for the expected performance of automatic preprocessing in large sleep EEG databases.

PsychophysiologyVol. 62(2)
Semmelweis University (HU), Radboud University Nijmegen (NL), Radboud University Medical Center (NL)
Magyar Tudományos Akadémia, Nemzeti Kutatási Fejlesztési és Innovációs Hivatal, Nemzeti Kutatási, Fejlesztési és Innovaciós Alap, National Research, Development and Innovation Office
Openalex Percentile: Top 23%
Sleep and Wakefulness Research
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.