Understanding the voltaic cell-like nature of moist cellulose thread through the development of a modified version of J.C. Bose’s strain cell: A crucial property for cellulose-based biomedical sensors

Cellulose is considered an important material for biomedical sensor development. In the recent past, several experiments have been conducted to explore several advantageous properties of cellulose for use in biomedical engineering. To investigate the electrical properties of a material, using laboratory-based electrochemical cells is considered a simple technique. It is known that ideally, there should not exist any potential difference (P.D.) between two identical wires obtained from the same piece of metal when connected in the form of an electrochemical cell, with water as the electrolyte. However, in the year 1900, Acharya J.C. Bose had experimentally proved through his Strain Cell instrument that even when two identical metallic pieces, in the form of electrodes obtained from the same metal wire (immersed in water), are connected to a sensitive galvanometer, there exists a minute P.D. between them. In recent times, various experiments have been conducted to develop low-cost modified galvanic cells using cotton salt bridges. In view of this, first, a modified strain cell setup was developed in the laboratory to repeat J.C. Bose’s experiment, and then a single electrode was replaced with moist cotton thread as a stable source of cellulose, connected from electrode to electrolyte to check if there is any qualitative variation in the phenomenon. A similar stable peak voltage, though of a different value as compared to that obtained in the original modified Strain Cell setup, was recorded, thereby confirming a voltaic-cell-like property of the moist cotton thread as well. Identification of such peculiar properties of cellulose in the form of moist cotton-based voltaic cells may help in the development of various types of cellulose-based biomedical sensors.

Authors

Institutions

Publication Details

Journal
INDIAN JOURNAL OF PHYSIOLOGY AND ALLIED SCIENCES
Published
2024-12-24
DOI
https://doi.org/10.55184/ijpas.v76i04.270
Primary Topic
Photoreceptor and optogenetics research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Understanding the voltaic cell-like nature of moist cellulose thread through the development of a modified version of J.C. Bose’s strain cell: A crucial property for cellulose-based biomedical sensors

Barnini Bhattacharya, Shibsankar Roy, Ritwik Haldar, Kuntal Ghosh et al.
INDIAN JOURNAL OF PHYSIOLOGY AND ALLIED SCIENCES
Photoreceptor and optogenetics research
article

Understanding the voltaic cell-like nature of moist cellulose thread through the development of a modified version of J.C. Bose’s strain cell: A crucial property for cellulose-based biomedical sensors

Barnini Bhattacharya, Shibsankar Roy, Ritwik Haldar, Kuntal Ghosh, Bijay Bal
article en

Abstract

Cellulose is considered an important material for biomedical sensor development. In the recent past, several experiments have been conducted to explore several advantageous properties of cellulose for use in biomedical engineering. To investigate the electrical properties of a material, using laboratory-based electrochemical cells is considered a simple technique. It is known that ideally, there should not exist any potential difference (P.D.) between two identical wires obtained from the same piece of metal when connected in the form of an electrochemical cell, with water as the electrolyte. However, in the year 1900, Acharya J.C. Bose had experimentally proved through his Strain Cell instrument that even when two identical metallic pieces, in the form of electrodes obtained from the same metal wire (immersed in water), are connected to a sensitive galvanometer, there exists a minute P.D. between them. In recent times, various experiments have been conducted to develop low-cost modified galvanic cells using cotton salt bridges. In view of this, first, a modified strain cell setup was developed in the laboratory to repeat J.C. Bose’s experiment, and then a single electrode was replaced with moist cotton thread as a stable source of cellulose, connected from electrode to electrolyte to check if there is any qualitative variation in the phenomenon. A similar stable peak voltage, though of a different value as compared to that obtained in the original modified Strain Cell setup, was recorded, thereby confirming a voltaic-cell-like property of the moist cotton thread as well. Identification of such peculiar properties of cellulose in the form of moist cotton-based voltaic cells may help in the development of various types of cellulose-based biomedical sensors.

INDIAN JOURNAL OF PHYSIOLOGY AND ALLIED SCIENCESVol. 76(04)
University of Calcutta (IN), Saha Institute of Nuclear Physics (IN), Indian Statistical Institute (IN)
Indian Statistical Institute
Openalex Percentile: Top 73%
Photoreceptor and optogenetics research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.