A Compact 2-D photonic crystal biomedical sensor for enhanced glucose concentration detection in urine

This study introduces a 2-D Photonic Crystal (PhC) biosensor designed, simulated, and evaluated for detecting glucose concentrations in urine by utilizing refractive index variations. The sensor demonstrates exceptional performance, achieving a sensitivity of 20,040.30 nm/RIU for glucose levels ranging from 0-15 mg/dl, a quality factor of 10,424.55, and a detection limit as low as 8 × 10<sup>-10</sup>, surpassing benchmarks reported in the literature. With compact dimensions of 16.8 × 17.6 µm<sup>2</sup> and compatibility with modern fabrication techniques, the proposed design is well suited for integration into portable diagnostic devices. A comprehensive comparative analysis underscores its superior sensitivity, ultra-high quality factor, and compact design, establishing it as a major advancement in glucose detection technology.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-02-10
DOI
https://doi.org/10.1038/s41598-025-87547-x
Citations
12
Primary Topic
Photonic Crystals and Applications
Type
article
Field-Weighted Citation Impact
14.96
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Compact 2-D photonic crystal biomedical sensor for enhanced glucose concentration detection in urine

Mahmoud M. Hamed, Kareem A. Badawi, Nazmi A. Mohammed
12 citations
Scientific Reports
Photonic Crystals and Applications
14.96
article

A Compact 2-D photonic crystal biomedical sensor for enhanced glucose concentration detection in urine

Mahmoud M. Hamed, Kareem A. Badawi, Nazmi A. Mohammed
article en
12 citations

Abstract

This study introduces a 2-D Photonic Crystal (PhC) biosensor designed, simulated, and evaluated for detecting glucose concentrations in urine by utilizing refractive index variations. The sensor demonstrates exceptional performance, achieving a sensitivity of 20,040.30 nm/RIU for glucose levels ranging from 0-15 mg/dl, a quality factor of 10,424.55, and a detection limit as low as 8 × 10<sup>-10</sup>, surpassing benchmarks reported in the literature. With compact dimensions of 16.8 × 17.6 µm<sup>2</sup> and compatibility with modern fabrication techniques, the proposed design is well suited for integration into portable diagnostic devices. A comprehensive comparative analysis underscores its superior sensitivity, ultra-high quality factor, and compact design, establishing it as a major advancement in glucose detection technology.

Scientific ReportsVol. 15(1)
Higher Technological Institute (EG), Higher Institute of Engineering (EG)
Openalex Percentile: Top 1%
Photonic Crystals and Applications
14.96
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.