Radiological and histological assessment of a novel interlocking three-dimensional miniplate for mandibular angle fractures: an animal study

BACKGROUND Open reduction and internal fixation are considered the gold standard for managing mandibular fractures, as they effectively restore anatomical structure and functionality. Three-dimensional (3D) miniplates were developed to obtain a geometrically stable structure. However, the rigid structure of 3D miniplate may cause screw holes to be located within the fracture lines or directly above important anatomical structures. Hence, we have developed customizable interlocking 3D miniplates that allow for modifications in the configuration of the horizontal miniplates and vertical cross-struts to meet specific requirements. METHODS This study included 24 goats divided into 2 groups: interlocking 3D miniplate and standard plate. Each group was further divided into subgroups sacrificed on Days 5, 28, and 56. Radiological assessments were performed to evaluate bone, muscle, peri-implant bone, and peri-implant muscle density. Histological assessments were performed using Masson's trichome (MT) for bone healing evaluation and hematoxylin and eosin (H&E) staining for biocompatibility. RESULTS Radiological assessment indicated an increase in density across all measured parameters from Day 5 to 56. Histological evaluation from MT staining showed a significantly higher fibrocartilage in the interlocking 3D miniplate group (6.109%, IQR 1.453–10.828) compared to standard plate (1.311%, IQR 0.636–2.553; p = 0.001). Furthermore, H&E staining showed significantly higher inflammatory cell counts in the standard group on Days 28 and 56 compared to the interlocking 3D miniplate group (p = 0.027). CONCLUSIONS This study concluded that the interlocking 3D miniplate showed better bone healing properties and biocompatibility than the standard plate.

Authors

Institutions

Publication Details

Journal
Medical Journal of Indonesia
Published
2025-02-10
DOI
https://doi.org/10.13181/mji.oa.247567
Primary Topic
Facial Trauma and Fracture Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Radiological and histological assessment of a novel interlocking three-dimensional miniplate for mandibular angle fractures: an animal study

Bambang Pontjo Priosoeryanto, Ahmad Jabir Rahyussalim, Deni Noviana, Aria Kekalih et al.
Medical Journal of Indonesia
Facial Trauma and Fracture Management
article

Radiological and histological assessment of a novel interlocking three-dimensional miniplate for mandibular angle fractures: an animal study

Bambang Pontjo Priosoeryanto, Ahmad Jabir Rahyussalim, Deni Noviana, Aria Kekalih, Chaula L. Sukasah, Sugeng Supriadi, Prasetyanugraheni Kreshanti, Mendy Juniaty Hatibie
article en

Abstract

BACKGROUND Open reduction and internal fixation are considered the gold standard for managing mandibular fractures, as they effectively restore anatomical structure and functionality. Three-dimensional (3D) miniplates were developed to obtain a geometrically stable structure. However, the rigid structure of 3D miniplate may cause screw holes to be located within the fracture lines or directly above important anatomical structures. Hence, we have developed customizable interlocking 3D miniplates that allow for modifications in the configuration of the horizontal miniplates and vertical cross-struts to meet specific requirements. METHODS This study included 24 goats divided into 2 groups: interlocking 3D miniplate and standard plate. Each group was further divided into subgroups sacrificed on Days 5, 28, and 56. Radiological assessments were performed to evaluate bone, muscle, peri-implant bone, and peri-implant muscle density. Histological assessments were performed using Masson's trichome (MT) for bone healing evaluation and hematoxylin and eosin (H&E) staining for biocompatibility. RESULTS Radiological assessment indicated an increase in density across all measured parameters from Day 5 to 56. Histological evaluation from MT staining showed a significantly higher fibrocartilage in the interlocking 3D miniplate group (6.109%, IQR 1.453–10.828) compared to standard plate (1.311%, IQR 0.636–2.553; p = 0.001). Furthermore, H&E staining showed significantly higher inflammatory cell counts in the standard group on Days 28 and 56 compared to the interlocking 3D miniplate group (p = 0.027). CONCLUSIONS This study concluded that the interlocking 3D miniplate showed better bone healing properties and biocompatibility than the standard plate.

Medical Journal of IndonesiaVol. 33(4)
IPB University (ID), University of Indonesia (ID), Rumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo (ID), Sam Ratulangi University (ID)
Openalex Percentile: Top 96%
Facial Trauma and Fracture Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.