CLINICAL COMPARISON OF FIXED-BEARING VERSUS MOBILE-BEARING TOTAL ANKLE ARTHROPLASTIES

Aims We compared the clinical outcomes of a fixed bearing (Infinity) and a mobile bearing (Zenith) ankle replacement in a demographically similar group of patients, from a single, non designer centre. Methods Between December 2010 and May 2016, 118 consecutive mobile bearing prostheses (Zenith) and between September 2017 and November 2019, 118 consecutive fixed bearing (Infinity) prostheses were implanted in a total cohort of 230 patients. Demographic, clinical, and patient reported outcome measures (PROMs) data were collected. The end point of the study was failure of the implant requiring revision of one or more of the components. Kaplan Meier survival tables were generated. Results Demographics were similar for both groups (age, pre-operative arthritic diagnosis and co-morbidities). 32 patients (36 ankles) died during follow-up, but none required revision. Of the surviving 198 patients (200 ankles; 93 Zenith, 107 Infinity), mean follow-up was 9.1 years (6.0 – 13.1 years) for Zenith and 5.0 years for Infinity (3.6 – 6.8 years). A total of 11 implants (9.3%) failed for Zenith and 1 implant (0.8%) failed for Infinity, requiring revision. Average time to failure for Zenith was 3.4 years (0.4 – 10.5 years) and the time to failure for Infinity was 4.1 years. Implant survival at five years, using revision as an endpoint, was 91.3% for Zenith and 98.7% for Infinity. There was a mean improvement in Manchester-Oxford Foot and Ankle Questionnaire (MOXFQ) from 85.0 to 32.8 for Zenith and 79.3 to 26.4 for Infinity, and visual analogue scale (VAS) scores from 7.0 to 3.2 for Zenith and 6.9 to 2.7 for Infinity. The commonest reason for revision was aseptic loosening for both implants. Conclusion Our results show a significantly better survivorship for the fixed bearing over the mobile bearing prosthesis. Whilst the fixed bearing prosthesis had better PROMS scores, this was not significant.

Authors

Institutions

Publication Details

Journal
Orthopaedic Proceedings
Published
2025-02-10
DOI
https://doi.org/10.1302/1358-992x.2025.1.021
Primary Topic
Foot and Ankle Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CLINICAL COMPARISON OF FIXED-BEARING VERSUS MOBILE-BEARING TOTAL ANKLE ARTHROPLASTIES

Robert Smith, Michael Karski, J. Ring, James H. Davenport et al.
Orthopaedic Proceedings
Foot and Ankle Surgery
article

CLINICAL COMPARISON OF FIXED-BEARING VERSUS MOBILE-BEARING TOTAL ANKLE ARTHROPLASTIES

Robert Smith, Michael Karski, J. Ring, James H. Davenport, Timothy M. Clough, S Bitar
article en

Abstract

Aims We compared the clinical outcomes of a fixed bearing (Infinity) and a mobile bearing (Zenith) ankle replacement in a demographically similar group of patients, from a single, non designer centre. Methods Between December 2010 and May 2016, 118 consecutive mobile bearing prostheses (Zenith) and between September 2017 and November 2019, 118 consecutive fixed bearing (Infinity) prostheses were implanted in a total cohort of 230 patients. Demographic, clinical, and patient reported outcome measures (PROMs) data were collected. The end point of the study was failure of the implant requiring revision of one or more of the components. Kaplan Meier survival tables were generated. Results Demographics were similar for both groups (age, pre-operative arthritic diagnosis and co-morbidities). 32 patients (36 ankles) died during follow-up, but none required revision. Of the surviving 198 patients (200 ankles; 93 Zenith, 107 Infinity), mean follow-up was 9.1 years (6.0 – 13.1 years) for Zenith and 5.0 years for Infinity (3.6 – 6.8 years). A total of 11 implants (9.3%) failed for Zenith and 1 implant (0.8%) failed for Infinity, requiring revision. Average time to failure for Zenith was 3.4 years (0.4 – 10.5 years) and the time to failure for Infinity was 4.1 years. Implant survival at five years, using revision as an endpoint, was 91.3% for Zenith and 98.7% for Infinity. There was a mean improvement in Manchester-Oxford Foot and Ankle Questionnaire (MOXFQ) from 85.0 to 32.8 for Zenith and 79.3 to 26.4 for Infinity, and visual analogue scale (VAS) scores from 7.0 to 3.2 for Zenith and 6.9 to 2.7 for Infinity. The commonest reason for revision was aseptic loosening for both implants. Conclusion Our results show a significantly better survivorship for the fixed bearing over the mobile bearing prosthesis. Whilst the fixed bearing prosthesis had better PROMS scores, this was not significant.

Orthopaedic ProceedingsVol. 107-B(SUPP_1)
Wrightington Hospital (GB)
Openalex Percentile: Top 97%
Foot and Ankle Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.