Edge-to-edge repair with ring annuloplasty for post-transplant biopsy-related tricuspid regurgitation

We experienced an early biopsy-related tricuspid regurgitation post-transplant. Transthoracic and transoesophageal echocardiography showed a frail anterior leaflet with a possible ruptured chorda. The tricuspid valve was inspected, and a ruptured chorda was noted in the anterior leaflet with a single torn chorda on the septal leaflet. The corresponding papillary muscle was difficult to identify. The patient underwent successful tricuspid valve repair with edge-to-edge repair and ring annuloplasty. Compared to a complex repair procedure such as the replacement of multiple artificial chordae, the edge-to-edge repair to correct prolapse without creating a gradient across the valve is reproducible.

Authors

Institutions

Publication Details

Journal
Multimedia Manual of Cardio-Thoracic Surgery
Published
2025-02-10
DOI
https://doi.org/10.1510/mmcts.2024.140
Primary Topic
Transplantation: Methods and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Edge-to-edge repair with ring annuloplasty for post-transplant biopsy-related tricuspid regurgitation

Corazon De La Pena, Sooyun Caroline Tavolacci, Suguru Ohira
Multimedia Manual of Cardio-Thoracic Surgery
Transplantation: Methods and Outcomes
article

Edge-to-edge repair with ring annuloplasty for post-transplant biopsy-related tricuspid regurgitation

Corazon De La Pena, Sooyun Caroline Tavolacci, Suguru Ohira
article en

Abstract

We experienced an early biopsy-related tricuspid regurgitation post-transplant. Transthoracic and transoesophageal echocardiography showed a frail anterior leaflet with a possible ruptured chorda. The tricuspid valve was inspected, and a ruptured chorda was noted in the anterior leaflet with a single torn chorda on the septal leaflet. The corresponding papillary muscle was difficult to identify. The patient underwent successful tricuspid valve repair with edge-to-edge repair and ring annuloplasty. Compared to a complex repair procedure such as the replacement of multiple artificial chordae, the edge-to-edge repair to correct prolapse without creating a gradient across the valve is reproducible.

Multimedia Manual of Cardio-Thoracic SurgeryVol. 2025
Westchester Medical Center (US)
Openalex Percentile: Top 96%
Transplantation: Methods and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Edge-to-edge repair with ring annuloplasty for post-transplant biopsy-related tricuspid regurgitation — Corazon De La Pena, Sooyun Caroline Tavolacci, et al. · Multimedia Manual of Cardio-Thoracic Surgery (2025) | TGRS Research Map | TGRS