Large-temperature-lift energy storage heat transformer for deep thermal energy utilization

The features of low grade and instability hinder the extensive utilization of renewable energy. Energy upgrading technology is needed to turn unusable renewable energy into usable energy, and energy storage systems are also required to solve the mismatch problem between energy sources and end users. Therefore, the energy storage heat transformer (ESHT) based on the desorption-absorption cycle has been proposed and regarded as a promising solution. To further reduce the heat input temperature and improve the cycle performance for deep utilization of renewable energy, a novel two-stage ESHT cycle is proposed and investigated. Preliminary experiments are conducted and used to validate the established dynamic model. Then, the performance under different working conditions are compared between the basic and two-stage ESHT cycles. Results show that one of the two solution tanks in the two-stage ESHT achieves a higher concentration compared to basic ESHT, increasing from 55.7 % to 65 % with the same temperature lift of 30 °C. The energy storage density (ESD) is significantly improved from 51.0 kWh/m 3 to 96.1 kWh/m 3 with similar energy storage efficiency (ESE) and exergy efficiency (EXE). A maximum temperature lift of 50 °C is reached under an input temperature of 60 °C. A minimum heat input temperature of 55 °C is achieved with a temperature lift of 35 °C. This work aims to provide references and suggestions for the improvement of absorption-based ESHT. • Two-stage experiment has been conducted to demonstrate the feasibility. • The maximum temperature lift is improved from 30 °C to 50 °C. • The energy storage density is improved from 51.0 kWh/m 3 to 96.1 kWh/m 3 . • The minimum input temperature of 55 °C is achieved with a lift of 35 °C.

Authors

Institutions

Publication Details

Journal
Applied Energy
Published
2025-02-10
DOI
https://doi.org/10.1016/j.apenergy.2025.125481
Citations
11
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
7.85

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Large-temperature-lift energy storage heat transformer for deep thermal energy utilization

Wei Wu, Zhixiong Ding
11 citations
Applied Energy
Adsorption and Cooling Systems
7.85
article

Large-temperature-lift energy storage heat transformer for deep thermal energy utilization

Wei Wu, Zhixiong Ding
article en
11 citations

Abstract

The features of low grade and instability hinder the extensive utilization of renewable energy. Energy upgrading technology is needed to turn unusable renewable energy into usable energy, and energy storage systems are also required to solve the mismatch problem between energy sources and end users. Therefore, the energy storage heat transformer (ESHT) based on the desorption-absorption cycle has been proposed and regarded as a promising solution. To further reduce the heat input temperature and improve the cycle performance for deep utilization of renewable energy, a novel two-stage ESHT cycle is proposed and investigated. Preliminary experiments are conducted and used to validate the established dynamic model. Then, the performance under different working conditions are compared between the basic and two-stage ESHT cycles. Results show that one of the two solution tanks in the two-stage ESHT achieves a higher concentration compared to basic ESHT, increasing from 55.7 % to 65 % with the same temperature lift of 30 °C. The energy storage density (ESD) is significantly improved from 51.0 kWh/m 3 to 96.1 kWh/m 3 with similar energy storage efficiency (ESE) and exergy efficiency (EXE). A maximum temperature lift of 50 °C is reached under an input temperature of 60 °C. A minimum heat input temperature of 55 °C is achieved with a temperature lift of 35 °C. This work aims to provide references and suggestions for the improvement of absorption-based ESHT. • Two-stage experiment has been conducted to demonstrate the feasibility. • The maximum temperature lift is improved from 30 °C to 50 °C. • The energy storage density is improved from 51.0 kWh/m 3 to 96.1 kWh/m 3 . • The minimum input temperature of 55 °C is achieved with a lift of 35 °C.

Applied EnergyVol. 384
City University of Hong Kong (HK), City University of Hong Kong, Shenzhen Research Institute (CN)
National Natural Science Foundation of China, Research Grants Council, University Grants Committee, Science, Technology and Innovation Commission of Shenzhen Municipality
Affordable and clean energy
Openalex Percentile: Top 2%
Adsorption and Cooling Systems
7.85
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.