A new empirical model of the 2-dimensional ionisation probability ϕ(ρr, ρz) described by an analytical function

Abstract For quantitative electron probe microanalysis matrix effects have to be considered. Conventional matrix correction procedures in use today assume a homogeneous composition for the bulk sample (known as ZAF correction) or heterogeneity only in depth for thin films ( ϕ ( ρz ) models). But when heterogeneity is expected in lateral directions, only Monte Carlo and deterministic simulations could be used for accurate matrix correction. These simulations are computationally expensive and slow. In this work, we introduce a novel analytical model for the multi-dimensional ionisation probability distribution ϕ ( ρr, ρz ) for a material bombarded with electrons, which could be used for fast matrix correction as an alternative to simulations. By fitting the model onto ionisation probability distributions generated by Monte Carlo simulations, we show that our model can adequately describe the simulated distributions.

Authors

Institutions

Publication Details

Journal
IOP Conference Series Materials Science and Engineering
Published
2025-02-01
DOI
https://doi.org/10.1088/1757-899x/1324/1/012001
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A new empirical model of the 2-dimensional ionisation probability ϕ(ρr, ρz) described by an analytical function

P. Pinard, Gaurav Achuda, Manuel Torrilhon, Jonas Bünger et al.
IOP Conference Series Materials Science and Engineering
Radiation Detection and Scintillator Technologies
article

A new empirical model of the 2-dimensional ionisation probability ϕ(ρr, ρz) described by an analytical function

P. Pinard, Gaurav Achuda, Manuel Torrilhon, Jonas Bünger, S. Richter
article en

Abstract

Abstract For quantitative electron probe microanalysis matrix effects have to be considered. Conventional matrix correction procedures in use today assume a homogeneous composition for the bulk sample (known as ZAF correction) or heterogeneity only in depth for thin films ( ϕ ( ρz ) models). But when heterogeneity is expected in lateral directions, only Monte Carlo and deterministic simulations could be used for accurate matrix correction. These simulations are computationally expensive and slow. In this work, we introduce a novel analytical model for the multi-dimensional ionisation probability distribution ϕ ( ρr, ρz ) for a material bombarded with electrons, which could be used for fast matrix correction as an alternative to simulations. By fitting the model onto ionisation probability distributions generated by Monte Carlo simulations, we show that our model can adequately describe the simulated distributions.

IOP Conference Series Materials Science and EngineeringVol. 1324(1)
Oxford Instruments (United Kingdom) (GB), RWTH Aachen University (DE)
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A new empirical model of the 2-dimensional ionisation probability ϕ(ρr, ρz) described by an analytical function — P. Pinard, Gaurav Achuda, et al. · IOP Conference Series Materials Science and Engineering (2025) | TGRS Research Map | TGRS