A point-of-care, label-free OECT sensor for uric acid detection: Validation in human saliva

• Development of a novel label-free PEDOT:PSS sensor for uric acid in human saliva. • Use of potentiodynamic detection to enhance accuracy. • Validation in real saliva with an independent method, ensuring high reliability. • Simplified design allows rapid measurements, compatible with POC platforms. • Integration with portable electronics with Bluetooth data transmission. This study presents the development of an organic electrochemical transistor (OECT) sensor for the detection of uric acid (UA) in human saliva, employing a potentiodynamic measurement technique. Unlike many existing (bio)sensors, this device is entirely based on the organic semiconductor poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS), which simplifies manufacturing and maintenance and reduces production costs. First of all, a systematic comparison between the potentiostatic and potentiodynamic sensing performance in buffer solution is presented, which proves the superior accuracy (14 %), repeatability (5 %), and reproducibility (8 %) of the potentiodynamic approach. In particular, a sensitivity of 59 µS dec −1 is obtained in the concentration range 10 – 350 µM UA, with a detection limit of 1 µM. Selectivity studies and subsequent validation of the potentiodynamic OECT sensor in human saliva with an independent method specific for salivary UA quantification is then presented, after which we show the application of our sensor to salivary UA monitoring during food intake, as well as the attempt to analyze swine saliva. Furthermore, as the sensor's design supports integration with point-of-care platforms, we demonstrate its functionality with portable electronics and smartphone connectivity. This approach enables rapid, real-time monitoring, offering a practical and cost-effective solution for non-invasive UA detection in clinical settings.

Authors

Institutions

Publication Details

Journal
Electrochimica Acta
Published
2025-02-10
DOI
https://doi.org/10.1016/j.electacta.2025.145834
Citations
14
Primary Topic
Salivary Gland Disorders and Functions
Type
article
Field-Weighted Citation Impact
16.30
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A point-of-care, label-free OECT sensor for uric acid detection: Validation in human saliva

Beatrice Fraboni, Francesco Decataldo, Francesca Ceccardi, Erika Scavetta et al.
14 citations
Electrochimica Acta
Salivary Gland Disorders and Functions
16.30
article

A point-of-care, label-free OECT sensor for uric acid detection: Validation in human saliva

Beatrice Fraboni, Francesco Decataldo, Francesca Ceccardi, Erika Scavetta, Federica Mariani, Isacco Gualandi, Vito Vurro, Marta Tessarolo
article en
14 citations

Abstract

• Development of a novel label-free PEDOT:PSS sensor for uric acid in human saliva. • Use of potentiodynamic detection to enhance accuracy. • Validation in real saliva with an independent method, ensuring high reliability. • Simplified design allows rapid measurements, compatible with POC platforms. • Integration with portable electronics with Bluetooth data transmission. This study presents the development of an organic electrochemical transistor (OECT) sensor for the detection of uric acid (UA) in human saliva, employing a potentiodynamic measurement technique. Unlike many existing (bio)sensors, this device is entirely based on the organic semiconductor poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS), which simplifies manufacturing and maintenance and reduces production costs. First of all, a systematic comparison between the potentiostatic and potentiodynamic sensing performance in buffer solution is presented, which proves the superior accuracy (14 %), repeatability (5 %), and reproducibility (8 %) of the potentiodynamic approach. In particular, a sensitivity of 59 µS dec −1 is obtained in the concentration range 10 – 350 µM UA, with a detection limit of 1 µM. Selectivity studies and subsequent validation of the potentiodynamic OECT sensor in human saliva with an independent method specific for salivary UA quantification is then presented, after which we show the application of our sensor to salivary UA monitoring during food intake, as well as the attempt to analyze swine saliva. Furthermore, as the sensor's design supports integration with point-of-care platforms, we demonstrate its functionality with portable electronics and smartphone connectivity. This approach enables rapid, real-time monitoring, offering a practical and cost-effective solution for non-invasive UA detection in clinical settings.

Electrochimica ActaVol. 519
Istituto Nazionale di Fisica Nucleare, Sezione di Bologna (IT), University of Bologna (IT)
Zero hunger
Openalex Percentile: Top 1%
Salivary Gland Disorders and Functions
16.30
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.