Perbandingan Aktivitas Enzim Cholinesterase Serum dengan Metode Fotometri Teknik Sample Start dan Substrat Start

Cholinesterase examination related to liver function and carried out by kinetic photometric method with two type reagent addition techniques, namely sample start and substrat start. Both techniques are related to incubation time during examination which affects waiting time for laboratory service result. This study aims to determine comparison of serum cholinesterase activity measured by sample start and substrat start techniques. The research was conducted in May 2024 at Clinical Chemistry Laboratory of Bandung Polytechnic Health. The research using Paired Sample T-test of 30 serum samples measured cholinesterase activity at 405 nm wavelength photometer using sample start and substrat start techniques so that 60 research data were obtained. The result of Paired Sample T-test showed that serum cholinesterase activity with sample start technique had lower trend value than serum cholinesterase activity with substrat start technique and there was no clinical effect with an analytical difference in cholinesterase activity measured by both techniques indicated by the Sig value 0.000 and TE% < TEa% that 4.72% < 8.7%. Therefore, the sample start and substrat start techniques in photometric method of serum cholinesterase activity can be applied for daily testing because the difference in value of two techniques has no clinical effect.

Authors

Institutions

Publication Details

Journal
Jurnal Medika Husada
Published
2024-10-31
DOI
https://doi.org/10.59744/jumeha.v4i2.74
Primary Topic
Computational Drug Discovery Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Perbandingan Aktivitas Enzim Cholinesterase Serum dengan Metode Fotometri Teknik Sample Start dan Substrat Start

Ani Riyani, Zuri Rismiarti, Rohayati Rohayati, Farha Salsabila Widigdo
Jurnal Medika Husada
Computational Drug Discovery Methods
article

Perbandingan Aktivitas Enzim Cholinesterase Serum dengan Metode Fotometri Teknik Sample Start dan Substrat Start

Ani Riyani, Zuri Rismiarti, Rohayati Rohayati, Farha Salsabila Widigdo
article en

Abstract

Cholinesterase examination related to liver function and carried out by kinetic photometric method with two type reagent addition techniques, namely sample start and substrat start. Both techniques are related to incubation time during examination which affects waiting time for laboratory service result. This study aims to determine comparison of serum cholinesterase activity measured by sample start and substrat start techniques. The research was conducted in May 2024 at Clinical Chemistry Laboratory of Bandung Polytechnic Health. The research using Paired Sample T-test of 30 serum samples measured cholinesterase activity at 405 nm wavelength photometer using sample start and substrat start techniques so that 60 research data were obtained. The result of Paired Sample T-test showed that serum cholinesterase activity with sample start technique had lower trend value than serum cholinesterase activity with substrat start technique and there was no clinical effect with an analytical difference in cholinesterase activity measured by both techniques indicated by the Sig value 0.000 and TE% < TEa% that 4.72% < 8.7%. Therefore, the sample start and substrat start techniques in photometric method of serum cholinesterase activity can be applied for daily testing because the difference in value of two techniques has no clinical effect.

Jurnal Medika HusadaVol. 4(2)
Politeknik Kesehatan Kemenkes Semarang (ID)
Openalex Percentile: Top 69%
Computational Drug Discovery Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Perbandingan Aktivitas Enzim Cholinesterase Serum dengan Metode Fotometri Teknik Sample Start dan Substrat Start — Ani Riyani, Zuri Rismiarti, et al. · Jurnal Medika Husada (2024) | TGRS Research Map | TGRS