Optimization of static heat loads of the PIP-II cryomodules based on prototype HB650 cryomodule test results

During the first cool down of the prototype HB650 cryomodule (pHB650 CM), high static heat loads have been measured compared to the estimation. Several analysis and calculations have been performed to explain this difference which led to cool down this cryomodule two additional times. Before each cool down, repairs and upgrades have been done, and instrumentations were added to identify the issues and quantify their impact on the heat loads. Based on these findings, the production cryomodule design and assembly process have been updated to align the future heat loads measurements with the estimations.

Authors

Institutions

Publication Details

Journal
OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)
Published
2024-10-25
DOI
https://doi.org/10.18429/jacow-linac2024-thpb029
Primary Topic
Superconducting Materials and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of static heat loads of the PIP-II cryomodules based on prototype HB650 cryomodule test results

Jeremiah Holzbauer, J. Subedi, J. Ozelis, J. Makara et al.
OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)
Superconducting Materials and Applications
article

Optimization of static heat loads of the PIP-II cryomodules based on prototype HB650 cryomodule test results

Jeremiah Holzbauer, J. Subedi, J. Ozelis, J. Makara, Vincent Roger, Michael J. White, Donato Passarelli, D. Porwisiak, J. Bernardini, Sungwoon Yoon, Alex Martinez, Benjamin Hansen
article en

Abstract

During the first cool down of the prototype HB650 cryomodule (pHB650 CM), high static heat loads have been measured compared to the estimation. Several analysis and calculations have been performed to explain this difference which led to cool down this cryomodule two additional times. Before each cool down, repairs and upgrades have been done, and instrumentations were added to identify the issues and quantify their impact on the heat loads. Based on these findings, the production cryomodule design and assembly process have been updated to align the future heat loads measurements with the estimations.

OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)
Fermi National Accelerator Laboratory (US)
Affordable and clean energy
Openalex Percentile: Top 76%
Superconducting Materials and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.