Feasibility Study of Hybrid Photovoltaic (PV)-Generator Set Power Plant at Palm Oil Mill

Kuko Palm Oil Mill, currently not interconnected with PLN electricity, relies on diesel-fueled generators of 1100 kVA and 650 kVA to meet its electrical needs. To reduce diesel consumption, a Hybrid Power Plant (PLTH) system comprising generators, batteries, and Photovoltaic (PV) panels is proposed. Optimization studies, evaluating technical and economic feasibility, are conducted using HOMER software. Optimal PLTH configuration includes 8,727 kW PV, 500 kW generator, 1,000 kW generator, 25,708 battery units, and 1,481 kW converter. PLTH generates 14,339,116 kWh/year, fulfilling PKS electricity requirements. Economic analysis yields NPC of Rp356,000,000,000, initial investment of Rp77,400,000,000, operation and maintenance costs of Rp21,600,000,000, and LCOE of Rp3,147/kWh. IRR stands at 22%, NPV is positive at Rp124,000,000,000, with a 3.5-year capital return. These results indicate PLTH feasibility both technically and economically

Authors

Institutions

Publication Details

Journal
PROtek Jurnal Ilmiah Teknik Elektro
Published
2025-01-22
DOI
https://doi.org/10.33387/protk.v12i1.7720
Primary Topic
Islanding Detection in Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility Study of Hybrid Photovoltaic (PV)-Generator Set Power Plant at Palm Oil Mill

Marhama Jelita, Riza Hadi Saputra
PROtek Jurnal Ilmiah Teknik Elektro
Islanding Detection in Power Systems
article

Feasibility Study of Hybrid Photovoltaic (PV)-Generator Set Power Plant at Palm Oil Mill

Marhama Jelita, Riza Hadi Saputra
article en

Abstract

Kuko Palm Oil Mill, currently not interconnected with PLN electricity, relies on diesel-fueled generators of 1100 kVA and 650 kVA to meet its electrical needs. To reduce diesel consumption, a Hybrid Power Plant (PLTH) system comprising generators, batteries, and Photovoltaic (PV) panels is proposed. Optimization studies, evaluating technical and economic feasibility, are conducted using HOMER software. Optimal PLTH configuration includes 8,727 kW PV, 500 kW generator, 1,000 kW generator, 25,708 battery units, and 1,481 kW converter. PLTH generates 14,339,116 kWh/year, fulfilling PKS electricity requirements. Economic analysis yields NPC of Rp356,000,000,000, initial investment of Rp77,400,000,000, operation and maintenance costs of Rp21,600,000,000, and LCOE of Rp3,147/kWh. IRR stands at 22%, NPV is positive at Rp124,000,000,000, with a 3.5-year capital return. These results indicate PLTH feasibility both technically and economically

PROtek Jurnal Ilmiah Teknik ElektroVol. 12(1)
Universitas Islam Negeri Sultan Syarif Kasim Riau (ID)
Openalex Percentile: Top 98%
Islanding Detection in Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Feasibility Study of Hybrid Photovoltaic (PV)-Generator Set Power Plant at Palm Oil Mill — Marhama Jelita, Riza Hadi Saputra · PROtek Jurnal Ilmiah Teknik Elektro (2025) | TGRS Research Map | TGRS