A MODEL OF FREE CONVECTION IN ABOVEGROUND VERTICAL FIRE TANKS WITH AN INTERNAL FLUE

It is proposed to install a flue that passes through a vertical reservoir from bottom to top and is connected to the facility's climate system, which allows the use of residual thermal energy of the outgoing airflow, which prevents freezing of the remaining water supply. It is shown that effective optimization involves the use of the results of full-scale or mathematical modeling of heat transfer processes in the tank, as well as inside the flue, tank walls and thermal insulation layers. The field of full-scale and numerical modeling included two liquids (water inside the tank and air inside the flue), an internal steel wall and a polyurethane insulating material covered with an external protective steel shell, as well as an external airspace. The numerical solution was obtained using the CFD code ANES for the entire domain by discretizing the control equations using finite volume methods. The proposed numerical model can be used to describe in detail the thermal phenomena occurring inside a fire tank with an internal flue and predict the thermal and hydrodynamic parameters of the structure under study.

Authors

Institutions

Publication Details

Journal
Problems of risk management in the technosphere
Published
2024-12-27
DOI
https://doi.org/10.61260/1998-8990-2025-2024-4-119-129
Primary Topic
Spacecraft and Cryogenic Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A MODEL OF FREE CONVECTION IN ABOVEGROUND VERTICAL FIRE TANKS WITH AN INTERNAL FLUE

N. P. Romanov, Anatoly Kuzmin, Alexander Krutolapov
Problems of risk management in the technosphere
Spacecraft and Cryogenic Technologies
article

A MODEL OF FREE CONVECTION IN ABOVEGROUND VERTICAL FIRE TANKS WITH AN INTERNAL FLUE

N. P. Romanov, Anatoly Kuzmin, Alexander Krutolapov
article en

Abstract

It is proposed to install a flue that passes through a vertical reservoir from bottom to top and is connected to the facility's climate system, which allows the use of residual thermal energy of the outgoing airflow, which prevents freezing of the remaining water supply. It is shown that effective optimization involves the use of the results of full-scale or mathematical modeling of heat transfer processes in the tank, as well as inside the flue, tank walls and thermal insulation layers. The field of full-scale and numerical modeling included two liquids (water inside the tank and air inside the flue), an internal steel wall and a polyurethane insulating material covered with an external protective steel shell, as well as an external airspace. The numerical solution was obtained using the CFD code ANES for the entire domain by discretizing the control equations using finite volume methods. The proposed numerical model can be used to describe in detail the thermal phenomena occurring inside a fire tank with an internal flue and predict the thermal and hydrodynamic parameters of the structure under study.

Problems of risk management in the technosphereVol. 2024(4)
Academy of the State Fire Service EMERCOM of Russia (RU)
Openalex Percentile: Top 55%
Spacecraft and Cryogenic Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.