Novel Method for the Estimation of Minoxidil and Aminexil in Marketed Formulation

The goal is to provide a simple, accurate, and sensitive HPTLC technique for estimating Minoxidil and Aminexil in topical solutions. Silica gel 60 F254 pre-coated TLC aluminium plates were used as the stationary phase in the procedure. Methanol: water (5:5) was the solvent system in use. At 254 nm, densitometric analysis was performed. The results showed that the Rf values for Aminexil and Minoxidil were 0.88 and 0.69, respectively. According to the findings, the scanning wavelength was 254 nm and was linear between 2 and 10 μg/spot for minoxidil and 6–14 μg/spot for aminexil. The %RSD was less than 2%. Minoxidil and Aminexil I were shown to have regression coefficients of 0.9983 and 0.9993, respectively. A simple, accurate, precise, and sensitive HPTLC approach is designed and validated in compliance with ICH criteria for measuring minoxidil and aminexil in combination in topical solution.

Authors

Publication Details

Journal
International Journal For Multidisciplinary Research
Published
2025-02-07
DOI
https://doi.org/10.36948/ijfmr.2025.v07i01.36314
Citations
1
Primary Topic
Viral Infectious Diseases and Gene Expression in Insects
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel Method for the Estimation of Minoxidil and Aminexil in Marketed Formulation

Judy Jays -, Rahul Natholia -, Huma Sulthana -
1 citations
International Journal For Multidisciplinary Research
Viral Infectious Diseases and Gene Expression in Insects
0.81
article

Novel Method for the Estimation of Minoxidil and Aminexil in Marketed Formulation

Judy Jays -, Rahul Natholia -, Huma Sulthana -
article en
1 citations

Abstract

The goal is to provide a simple, accurate, and sensitive HPTLC technique for estimating Minoxidil and Aminexil in topical solutions. Silica gel 60 F254 pre-coated TLC aluminium plates were used as the stationary phase in the procedure. Methanol: water (5:5) was the solvent system in use. At 254 nm, densitometric analysis was performed. The results showed that the Rf values for Aminexil and Minoxidil were 0.88 and 0.69, respectively. According to the findings, the scanning wavelength was 254 nm and was linear between 2 and 10 μg/spot for minoxidil and 6–14 μg/spot for aminexil. The %RSD was less than 2%. Minoxidil and Aminexil I were shown to have regression coefficients of 0.9983 and 0.9993, respectively. A simple, accurate, precise, and sensitive HPTLC approach is designed and validated in compliance with ICH criteria for measuring minoxidil and aminexil in combination in topical solution.

International Journal For Multidisciplinary ResearchVol. 7(1)
Openalex Percentile: Top 31%
Viral Infectious Diseases and Gene Expression in Insects
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.