Glass fibre-based FRCM systems under mild temperature exposures

Fibre Reinforced Cementitious Matrix (FRCM) systems have been widely used as an effective method for retrofitting existing structures. However, their durability against environmental actions remains partially unsolved. A comprehensive experimental study was carried out to investigate the influence of different temperature levels on the mechanical properties of two FRCM systems. The first system was composed of a combination of aramid and glass fibres as reinforcing textile, while the second system was strengthened with glass fibres only. Tests were carried out on dry bundles and textiles, mortar prisms, FRCM coupons and single-lap direct shear specimens. A specific thermal procedure was developed and employed to control the conditioning and testing phases. To investigate the impact of temperature exposure on the tensile and bond behaviour of the FRCM systems, capacity retention rates were evaluated and, in general, a decreasing trend was registered in terms of peak axial stress vs temperature. In terms of tensile properties, a similar negative impact of temperature was registered for both systems, with capacity retention rates ranging between 60 % and 70 % at the highest temperature levels tested. In terms of bond behaviour, temperature variations can potentially trigger a change in the failure mode, which was more pronounced for the system containing only glass fibres, for which lower retention rates were recorded, with a maximum reduction to 50 % at the highest temperature. The obtained outcomes demonstrated how even mild temperatures can potentially affect the tensile strength of these systems as well as their bond capacity when applied on masonry substrates. • Effects of controlled temperature variations on two FRCM systems were obtained. • A new thermal procedure was developed and successfully applied in all tests. • Tests were conducted on bundles, textiles, coupons and reinforced masonry wallets. • Tensile capacity was affected while bond failure modes shifted at high temperature. • Capacity retention rates used to compare effect of temperature for each test typology.

Authors

Institutions

Publication Details

Journal
Journal of Building Engineering
Published
2025-02-08
DOI
https://doi.org/10.1016/j.jobe.2025.112072
Citations
3
Primary Topic
Masonry and Concrete Structural Analysis
Type
article
Field-Weighted Citation Impact
2.86
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Glass fibre-based FRCM systems under mild temperature exposures

Matteo Canestri, Claudio Mazzotti, Francesca Ferretti
3 citations
Journal of Building Engineering
Masonry and Concrete Structural Analysis
2.86
article

Glass fibre-based FRCM systems under mild temperature exposures

Matteo Canestri, Claudio Mazzotti, Francesca Ferretti
article en
3 citations

Abstract

Fibre Reinforced Cementitious Matrix (FRCM) systems have been widely used as an effective method for retrofitting existing structures. However, their durability against environmental actions remains partially unsolved. A comprehensive experimental study was carried out to investigate the influence of different temperature levels on the mechanical properties of two FRCM systems. The first system was composed of a combination of aramid and glass fibres as reinforcing textile, while the second system was strengthened with glass fibres only. Tests were carried out on dry bundles and textiles, mortar prisms, FRCM coupons and single-lap direct shear specimens. A specific thermal procedure was developed and employed to control the conditioning and testing phases. To investigate the impact of temperature exposure on the tensile and bond behaviour of the FRCM systems, capacity retention rates were evaluated and, in general, a decreasing trend was registered in terms of peak axial stress vs temperature. In terms of tensile properties, a similar negative impact of temperature was registered for both systems, with capacity retention rates ranging between 60 % and 70 % at the highest temperature levels tested. In terms of bond behaviour, temperature variations can potentially trigger a change in the failure mode, which was more pronounced for the system containing only glass fibres, for which lower retention rates were recorded, with a maximum reduction to 50 % at the highest temperature. The obtained outcomes demonstrated how even mild temperatures can potentially affect the tensile strength of these systems as well as their bond capacity when applied on masonry substrates. • Effects of controlled temperature variations on two FRCM systems were obtained. • A new thermal procedure was developed and successfully applied in all tests. • Tests were conducted on bundles, textiles, coupons and reinforced masonry wallets. • Tensile capacity was affected while bond failure modes shifted at high temperature. • Capacity retention rates used to compare effect of temperature for each test typology.

Journal of Building EngineeringVol. 103
University of Bologna (IT)
Affordable and clean energy
Openalex Percentile: Top 12%
Masonry and Concrete Structural Analysis
2.86
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.