Variation in the degradation of stereoacuity via monocular blur across multiple stereotests

<i>Purpose</i>: Detecting changes in stereothresholds aids in the diagnosis and management of binocular vision disorders. However, there is variation in the stereoacuity levels measured across a range of stereotests. There are limited data assessing how stereotests respond to degradations of stereoacuity. Therefore, the aim of this study is to compare stereothresholds obtained from four different stereotests across different conditions of induced monocular blur. <i>Methods</i>: Stereoacuity was measured once for each Bangerter foil condition (no foil, 0.2 foil, 0.4 foil) using the Frisby, TNO, Lang-Stereopad and Asteroid stereotests. Inclusion criteria were age ≥18 years, no history of conditions that could impair stereoacuity, best-corrected monocular visual acuity of equal to or better than 0.3 logMAR, an interocular difference of less than 0.2 logMAR, up to date refractive correction (within the last 2 years) if required, and the ability to provide informed written consent. Significance of the differences in values between tests was calculated using the Kruskal-Wallis test, with further pairwise comparisons made via post-hoc analysis. <i>Results</i>: Fifty-one visually normal adults (67% female) of mean age 25 years ±8.35 were included. Statistically significant differences were achieved for most pairwise comparisons (<i>p</i> < .05), except when comparing TNO and Asteroid. The TNO and Lang-Stereopad tests degraded by the same median values between foil conditions, with Frisby showing the least median change between foils (0.135 median difference between 0.2 and 0.4 foils, <i>p</i> < .001). <i>Conclusions</i>: Stereotests detect stereoacuity degradation to varying extents, with the Asteroid test being most sensitive to change via monocular blur. The reasons for these differences lie in the varying methods of presentation. It is therefore recommended that test selection remains constant between appointments for the purpose of assessing subtle changes to aid patient management. Further evaluation of the ability to detect alterations in stereothresholds is required in people with impaired stereoacuity.

Authors

Institutions

Publication Details

Journal
Strabismus
Published
2025-02-06
DOI
https://doi.org/10.1080/09273972.2024.2448521
Primary Topic
Visual perception and processing mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Variation in the degradation of stereoacuity via monocular blur across multiple stereotests

Jignasa Mehta, Anna O’Connor, Jay Davies
Strabismus
Visual perception and processing mechanisms
article

Variation in the degradation of stereoacuity via monocular blur across multiple stereotests

Jignasa Mehta, Anna O’Connor, Jay Davies
article en

Abstract

<i>Purpose</i>: Detecting changes in stereothresholds aids in the diagnosis and management of binocular vision disorders. However, there is variation in the stereoacuity levels measured across a range of stereotests. There are limited data assessing how stereotests respond to degradations of stereoacuity. Therefore, the aim of this study is to compare stereothresholds obtained from four different stereotests across different conditions of induced monocular blur. <i>Methods</i>: Stereoacuity was measured once for each Bangerter foil condition (no foil, 0.2 foil, 0.4 foil) using the Frisby, TNO, Lang-Stereopad and Asteroid stereotests. Inclusion criteria were age ≥18 years, no history of conditions that could impair stereoacuity, best-corrected monocular visual acuity of equal to or better than 0.3 logMAR, an interocular difference of less than 0.2 logMAR, up to date refractive correction (within the last 2 years) if required, and the ability to provide informed written consent. Significance of the differences in values between tests was calculated using the Kruskal-Wallis test, with further pairwise comparisons made via post-hoc analysis. <i>Results</i>: Fifty-one visually normal adults (67% female) of mean age 25 years ±8.35 were included. Statistically significant differences were achieved for most pairwise comparisons (<i>p</i> < .05), except when comparing TNO and Asteroid. The TNO and Lang-Stereopad tests degraded by the same median values between foil conditions, with Frisby showing the least median change between foils (0.135 median difference between 0.2 and 0.4 foils, <i>p</i> < .001). <i>Conclusions</i>: Stereotests detect stereoacuity degradation to varying extents, with the Asteroid test being most sensitive to change via monocular blur. The reasons for these differences lie in the varying methods of presentation. It is therefore recommended that test selection remains constant between appointments for the purpose of assessing subtle changes to aid patient management. Further evaluation of the ability to detect alterations in stereothresholds is required in people with impaired stereoacuity.

StrabismusVol. 33(3)
University of Liverpool (GB)
Zero hunger
Openalex Percentile: Top 98%
Visual perception and processing mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.