Integrating voltammetry and substrate-enhanced luminescence for noninvasive glucose sensing

This study presents a novel noninvasive and enzyme-free dual sensor based on porous silicon (PSi) for the detection of D-glucose through tear fluid analysis. The sensor incorporates NaGdF 4 :20% Yb 3+ , 2% Er 3+ nanoparticles (YbEr-NPs) immobilized on a PSi substrate functionalized with a phenylboronic ester molecule. The YbEr-NPs enable luminescence-based sensing, exploiting the sensitivity of Er 3+ ions to the OH vibrational groups present in D-glucose. Electrodes fabricated on a PSi substrate allow for voltammetric analysis, providing a second detection method. The voltammetric sensor achieved a limit of detection (LoD) of 20 mg/dL in the range of 20–200 mg/dL, which is suitable for detecting D-glucose concentrations in the tear fluid of diabetic patients. The luminescence-based sensor, utilizing the red-to-green emission ratio of YbEr-NPs, reached a LoD of 140 mg/dL in the range of 10–70 mg/dL, covering the hyperglycemic range. The interaction between the YbEr-NPs and the PSi substrate led to the appearance of new emission bands and increased intensity, attributed to surface defects acting as an additional excitation source. The 556 nm emission band showed a strong dependence on the D-glucose concentration, improving the LoD to 110 mg/dL. This provides a novel strategy for D-glucose detection based on the effect of the molecule on the interaction between the Rare-earth-doped nanoparticles and the PSi substrate. This triple-sensing approach offers a promising solution for noninvasive glucose monitoring, enabling detection in both the hypoglycemic and hyperglycemic ranges. • Innovative non-invasive and enzyme-free D-glucose dual sensor. • Porous silicon-based sensors with Yb 3+ -and Er 3+ - doped NPs show enhanced emissions highly sensitive to D-glucose presence. • Dual sensing capability: voltammetry for low D-glucose concentrations and luminescence for high concentrations. • The highly sensitive NPs detect D-glucose without complex enzyme functionalization. • Potential for future non-invasive glucose detection in diabetic patients.

Authors

Institutions

Publication Details

Journal
Biosensors and Bioelectronics X
Published
2025-02-07
DOI
https://doi.org/10.1016/j.biosx.2025.100591
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integrating voltammetry and substrate-enhanced luminescence for noninvasive glucose sensing

Gabriel López-Peña, M. Ribagorda, Ana Pallarés Vilar, Miguel Manso‐Silván et al.
Biosensors and Bioelectronics X
Electrochemical sensors and biosensors
article

Integrating voltammetry and substrate-enhanced luminescence for noninvasive glucose sensing

Gabriel López-Peña, M. Ribagorda, Ana Pallarés Vilar, Miguel Manso‐Silván, Aida Jaafar, A. Arranz, Silvia Simón‐Fuente, Emma Martín Rodríguez
article en

Abstract

This study presents a novel noninvasive and enzyme-free dual sensor based on porous silicon (PSi) for the detection of D-glucose through tear fluid analysis. The sensor incorporates NaGdF 4 :20% Yb 3+ , 2% Er 3+ nanoparticles (YbEr-NPs) immobilized on a PSi substrate functionalized with a phenylboronic ester molecule. The YbEr-NPs enable luminescence-based sensing, exploiting the sensitivity of Er 3+ ions to the OH vibrational groups present in D-glucose. Electrodes fabricated on a PSi substrate allow for voltammetric analysis, providing a second detection method. The voltammetric sensor achieved a limit of detection (LoD) of 20 mg/dL in the range of 20–200 mg/dL, which is suitable for detecting D-glucose concentrations in the tear fluid of diabetic patients. The luminescence-based sensor, utilizing the red-to-green emission ratio of YbEr-NPs, reached a LoD of 140 mg/dL in the range of 10–70 mg/dL, covering the hyperglycemic range. The interaction between the YbEr-NPs and the PSi substrate led to the appearance of new emission bands and increased intensity, attributed to surface defects acting as an additional excitation source. The 556 nm emission band showed a strong dependence on the D-glucose concentration, improving the LoD to 110 mg/dL. This provides a novel strategy for D-glucose detection based on the effect of the molecule on the interaction between the Rare-earth-doped nanoparticles and the PSi substrate. This triple-sensing approach offers a promising solution for noninvasive glucose monitoring, enabling detection in both the hypoglycemic and hyperglycemic ranges. • Innovative non-invasive and enzyme-free D-glucose dual sensor. • Porous silicon-based sensors with Yb 3+ -and Er 3+ - doped NPs show enhanced emissions highly sensitive to D-glucose presence. • Dual sensing capability: voltammetry for low D-glucose concentrations and luminescence for high concentrations. • The highly sensitive NPs detect D-glucose without complex enzyme functionalization. • Potential for future non-invasive glucose detection in diabetic patients.

Biosensors and Bioelectronics XVol. 23
Universidad Complutense de Madrid (ES), Instituto de Ciencia de Materiales de Madrid (ES), Instituto Ramón y Cajal de Investigación Sanitaria (ES), Universidad Autónoma de Madrid (ES)
Comunidad de Madrid, Ministerio de Ciencia, Innovación y Universidades
Zero hunger
Openalex Percentile: Top 98%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.