Performance modelling of a two-bed silica gel-water pair adsorption chiller

• Adsorption chiller performance was improved with the heat and mass recovery model to overcome a discontinuous process. • An innovative technique including thermal energy storage for optimal stand-alone adsorption chiller during nighttime and low peak was carried out. • Performance evaluation revealed that COP increased from51 % - 62 % as well as SCP out of 750 W/kg −1500 W/kg. In this study, thermodynamic modelling of a two-bed silica gel-water pair adsorption cycle using the first and second laws of thermodynamics was presented. The adsorption chiller included thermal energy storage to overcome any limitations and unbalance during the night. Furthermore, the performance of heat and mass recovery model was compiled and then compared to the intermittent cycle. Results have proved that heat and mass recovery model significantly rose the system's performance while compare to a discontinuous process. With heat and mass recovery model, the system's performance (COP) rose from 51 to 63 %, while the Specific Cooling Power (SCP) rose out of750–1500 W/kg. In addition, performance parameters such as COP and SCP depend highly on desorption temperature and the maximum concentration of refrigerant during adsorption. This study results revealed that the driving temperature gives the greatest performance coefficient of the cycle 0.93 because of the mass variation of the adsorbate and the increase of maximum concentration of refrigerant W max from 0.07- 0.1 kg/kgSiO2. Since heat is expelled from the system during cooling phase, cooling water limits the chiller's performance at0.23; thenlonger cycle time lowers the driving heat consumption. Finally, adsorption chiller operation with thermal energy storage is predictable given the output hot water temperature of 95 °C.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2025-02-08
DOI
https://doi.org/10.1016/j.rineng.2025.104286
Citations
5
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
3.57
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance modelling of a two-bed silica gel-water pair adsorption chiller

C.N. Anyanwu, Fidelis I. Abam, Onyekwere Ojike, Mkpamdi Eke et al.
5 citations
Results in Engineering
Adsorption and Cooling Systems
3.57
article

Performance modelling of a two-bed silica gel-water pair adsorption chiller

C.N. Anyanwu, Fidelis I. Abam, Onyekwere Ojike, Mkpamdi Eke, Tagne Takote Brice Clausel
article en
5 citations

Abstract

• Adsorption chiller performance was improved with the heat and mass recovery model to overcome a discontinuous process. • An innovative technique including thermal energy storage for optimal stand-alone adsorption chiller during nighttime and low peak was carried out. • Performance evaluation revealed that COP increased from51 % - 62 % as well as SCP out of 750 W/kg −1500 W/kg. In this study, thermodynamic modelling of a two-bed silica gel-water pair adsorption cycle using the first and second laws of thermodynamics was presented. The adsorption chiller included thermal energy storage to overcome any limitations and unbalance during the night. Furthermore, the performance of heat and mass recovery model was compiled and then compared to the intermittent cycle. Results have proved that heat and mass recovery model significantly rose the system's performance while compare to a discontinuous process. With heat and mass recovery model, the system's performance (COP) rose from 51 to 63 %, while the Specific Cooling Power (SCP) rose out of750–1500 W/kg. In addition, performance parameters such as COP and SCP depend highly on desorption temperature and the maximum concentration of refrigerant during adsorption. This study results revealed that the driving temperature gives the greatest performance coefficient of the cycle 0.93 because of the mass variation of the adsorbate and the increase of maximum concentration of refrigerant W max from 0.07- 0.1 kg/kgSiO2. Since heat is expelled from the system during cooling phase, cooling water limits the chiller's performance at0.23; thenlonger cycle time lowers the driving heat consumption. Finally, adsorption chiller operation with thermal energy storage is predictable given the output hot water temperature of 95 °C.

Results in EngineeringVol. 25
University of Nigeria (NG), University of Calabar (NG)
Clean water and sanitation
Openalex Percentile: Top 8%
Adsorption and Cooling Systems
3.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Performance modelling of a two-bed silica gel-water pair adsorption chiller — C.N. Anyanwu, Fidelis I. Abam, et al. · Results in Engineering (2025) | TGRS Research Map | TGRS