Energy Saving Temperature Control of UAV Nest Inverter Air Conditioning Based on Variable Air Volume and DE Algorithm

The current temperature control model of UAV nest inverter air conditioning energy saving is mostly set to a single scheduling form, and the control efficiency is relatively low, resulting in a decline in the final energy consumption optimization ratio. Therefore, the design and practical verification of the temperature control method of UAV nest inverter air conditioning energy saving based on variable air volume and DE algorithm are proposed. According to the current measurement, the dynamic balance adjustment of the air volume and frequency of variable frequency air conditioning is carried out first. Based on this, the change trend of the thermal load of the UAV nest is analyzed. On this basis, combined with variable air volume and DE algorithm, the efficiency of control is strengthened, and the energy-saving temperature control model of UAV nest inverter air conditioning with variable air volume and DE algorithm is established, and the multi-level real-time balance correction method is used to achieve temperature control processing. The test results show that compared with DFT central air conditioning control method and deep learning intelligent energy-saving air conditioning control method, the energy consumption optimization ratio finally obtained by the variable air volume and DE calculation UAV machine nest variable frequency air conditioning energy-saving temperature control method is relatively high, which indicates that this time, with the help and support of variable air volume and DE algorithm, the designed energy-saving temperature control method of UAV nest inverter air conditioning is more flexible and changeable, and its own temperature control effect has been further improved, and the results have been verified in practice.

Authors

Institutions

Publication Details

Published
2024-11-29
DOI
https://doi.org/10.1109/icmsp64464.2024.10866090
Citations
1
Primary Topic
Safety and Risk Management
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Energy Saving Temperature Control of UAV Nest Inverter Air Conditioning Based on Variable Air Volume and DE Algorithm

Weihao Zhang, Zhuolei Chen, Hui Dong, Meiyan Yu et al.
1 citations
Safety and Risk Management
0.67
article

Energy Saving Temperature Control of UAV Nest Inverter Air Conditioning Based on Variable Air Volume and DE Algorithm

Weihao Zhang, Zhuolei Chen, Hui Dong, Meiyan Yu, Wenbin Wu
article en
1 citations

Abstract

The current temperature control model of UAV nest inverter air conditioning energy saving is mostly set to a single scheduling form, and the control efficiency is relatively low, resulting in a decline in the final energy consumption optimization ratio. Therefore, the design and practical verification of the temperature control method of UAV nest inverter air conditioning energy saving based on variable air volume and DE algorithm are proposed. According to the current measurement, the dynamic balance adjustment of the air volume and frequency of variable frequency air conditioning is carried out first. Based on this, the change trend of the thermal load of the UAV nest is analyzed. On this basis, combined with variable air volume and DE algorithm, the efficiency of control is strengthened, and the energy-saving temperature control model of UAV nest inverter air conditioning with variable air volume and DE algorithm is established, and the multi-level real-time balance correction method is used to achieve temperature control processing. The test results show that compared with DFT central air conditioning control method and deep learning intelligent energy-saving air conditioning control method, the energy consumption optimization ratio finally obtained by the variable air volume and DE calculation UAV machine nest variable frequency air conditioning energy-saving temperature control method is relatively high, which indicates that this time, with the help and support of variable air volume and DE algorithm, the designed energy-saving temperature control method of UAV nest inverter air conditioning is more flexible and changeable, and its own temperature control effect has been further improved, and the results have been verified in practice.

Fujian Electric Power Survey & Design Institute (CN)
Affordable and clean energy
Openalex Percentile: Top 19%
Safety and Risk Management
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.