Development of data acquisition module for intelligent balance

Wind tunnel force measurement experiment is the most basic and major experimental project in wind tunnel experiments, and the wind tunnel strain balance is the most important and indispensable measurement device in wind tunnel force measurement experiments. In this paper, for the polynomial balance calibration formula fitting method based on the least squares method can not eliminate the error caused by the nonlinearity of the balance to develop a neural network equipped with intelligent balance data acquisition module, by comparing with the traditional least squares method, the neural network can effectively improve the accuracy of the acquisition, and provide a new technical means for the comprehensive correction of the static error. In this paper, an intelligent balance data acquisition module equipped with neural network is developed, which can eliminate the nonlinear error brought by the insufficient rigidity of the balance in the calibration process. The hardware design and software design of the collector are given in this paper. Finally, the data accuracy is analysed according to the technical specification requirements.

Authors

Institutions

Publication Details

Published
2024-11-29
DOI
https://doi.org/10.1109/icmsp64464.2024.10867222
Primary Topic
Robotics and Automated Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of data acquisition module for intelligent balance

Liyan Qiao, Wang Liu, Feng Yun Jin, Lu Ke et al.
Robotics and Automated Systems
article

Development of data acquisition module for intelligent balance

Liyan Qiao, Wang Liu, Feng Yun Jin, Lu Ke, Yue Xu, Aihua Tao
article en

Abstract

Wind tunnel force measurement experiment is the most basic and major experimental project in wind tunnel experiments, and the wind tunnel strain balance is the most important and indispensable measurement device in wind tunnel force measurement experiments. In this paper, for the polynomial balance calibration formula fitting method based on the least squares method can not eliminate the error caused by the nonlinearity of the balance to develop a neural network equipped with intelligent balance data acquisition module, by comparing with the traditional least squares method, the neural network can effectively improve the accuracy of the acquisition, and provide a new technical means for the comprehensive correction of the static error. In this paper, an intelligent balance data acquisition module equipped with neural network is developed, which can eliminate the nonlinear error brought by the insufficient rigidity of the balance in the calibration process. The hardware design and software design of the collector are given in this paper. Finally, the data accuracy is analysed according to the technical specification requirements.

Harbin Institute of Technology (CN), China Aerodynamics Research and Development Center (CN)
Openalex Percentile: Top 67%
Robotics and Automated Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.