Remote Intelligent Diagnosis Technology for Leakage Current Based on Smart Measurement Devices

As user-side loads become more complex, the safety risks associated with leakage currents have increased. Neutral-wire miswiring, a common incorrect wiring method, can cause abnormal leakage current detection, leading to inaccurate leakage status readings. Most existing research focuses on leakage current analysis under normal wiring, with little attention to the effects of improper wiring. This paper examines the characteristics of neutral and live wire currents, as well as leakage currents, under three common types of improper wiring. Using the DBSCAN clustering algorithm, abnormal leakage current data is identified and categorized into individual and clustered abnormal users. For these abnormal user clusters, improper wiring is detected through the relationship between neutral and live wire currents and a multiple linear regression model. The proposed method is validated with experimental data from a single-phase smart IoT energy meter.

Authors

Institutions

Publication Details

Published
2024-11-29
DOI
https://doi.org/10.1109/icmsp64464.2024.10866646
Primary Topic
Smart Grid and Power Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Remote Intelligent Diagnosis Technology for Leakage Current Based on Smart Measurement Devices

Penghe Zhang, Kehan Chen, S L Chen, Runan Song et al.
Smart Grid and Power Systems
article

Remote Intelligent Diagnosis Technology for Leakage Current Based on Smart Measurement Devices

Penghe Zhang, Kehan Chen, S L Chen, Runan Song, Ganchao Chen, Zhongqiang Wu
article en

Abstract

As user-side loads become more complex, the safety risks associated with leakage currents have increased. Neutral-wire miswiring, a common incorrect wiring method, can cause abnormal leakage current detection, leading to inaccurate leakage status readings. Most existing research focuses on leakage current analysis under normal wiring, with little attention to the effects of improper wiring. This paper examines the characteristics of neutral and live wire currents, as well as leakage currents, under three common types of improper wiring. Using the DBSCAN clustering algorithm, abnormal leakage current data is identified and categorized into individual and clustered abnormal users. For these abnormal user clusters, improper wiring is detected through the relationship between neutral and live wire currents and a multiple linear regression model. The proposed method is validated with experimental data from a single-phase smart IoT energy meter.

North China Electric Power University (CN), China Electric Power Research Institute
Electric Power Research Institute
Affordable and clean energy
Openalex Percentile: Top 75%
Smart Grid and Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.