Optimization of Sectionalizer to Improve the Electrical Distribution Reliability Index of Gunungsitoli Distribution Network

The distribution network in the Gunungsitoli area contributes to major problems, namely customer problems. Disturbances and deepening often occur due to operational failures and fallen trees. The Gunungsitoli electrical system is islanded because it has a different magnitude system from most systems in Indonesia, so a component is needed that can reduce the impact of the disturbance, namely a sectionalizer. In reducing the impact, system optimization is carried out with the bee colony algorithm which will be compared with non-algorithmic results. On the PT. PLN Gunungsitoli network. After optimizing the sectionalizer on feeders with low reliability levels, an increase in reliability was obtained, namely: GMW.02, SAIFI = 0.2966 (56.7%), SAIDI = 16.281 (38.6%), GN.04 feeder SAIFI = 0.121 (78.9%) SAIDI = 15.33 (30.4%), GMW.07 feeder SAIFI = 0.306 (28.1 %) and SAIDI = 15.144 (34%). The level of reliability of the distribution network at the three feeders of PT.PLN ULP Gunungsitoli meets the SPLN and the Sectionalizer works according to its function.

Authors

Institutions

Publication Details

Published
2024-11-21
DOI
https://doi.org/10.1109/elticom64085.2024.10864631
Primary Topic
Power System Reliability and Maintenance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of Sectionalizer to Improve the Electrical Distribution Reliability Index of Gunungsitoli Distribution Network

Sihar Parlinggoman Panjaitan, Sheylin Wimora Lumban Tobing, Marzenius Gea
1 links
Power System Reliability and Maintenance
article

Optimization of Sectionalizer to Improve the Electrical Distribution Reliability Index of Gunungsitoli Distribution Network

Sihar Parlinggoman Panjaitan, Sheylin Wimora Lumban Tobing, Marzenius Gea
article en

Abstract

The distribution network in the Gunungsitoli area contributes to major problems, namely customer problems. Disturbances and deepening often occur due to operational failures and fallen trees. The Gunungsitoli electrical system is islanded because it has a different magnitude system from most systems in Indonesia, so a component is needed that can reduce the impact of the disturbance, namely a sectionalizer. In reducing the impact, system optimization is carried out with the bee colony algorithm which will be compared with non-algorithmic results. On the PT. PLN Gunungsitoli network. After optimizing the sectionalizer on feeders with low reliability levels, an increase in reliability was obtained, namely: GMW.02, SAIFI = 0.2966 (56.7%), SAIDI = 16.281 (38.6%), GN.04 feeder SAIFI = 0.121 (78.9%) SAIDI = 15.33 (30.4%), GMW.07 feeder SAIFI = 0.306 (28.1 %) and SAIDI = 15.144 (34%). The level of reliability of the distribution network at the three feeders of PT.PLN ULP Gunungsitoli meets the SPLN and the Sectionalizer works according to its function.

Universitas Sumatera Utara (ID)
Affordable and clean energy
Openalex Percentile: Top 67%
Power System Reliability and Maintenance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.