Near-Room-Temperature CO<sub>2</sub> Capacitive Sensors Based on Hybrid Polymer Sensitive Materials

Driven by growing concerns over the health hazards linked to carbon dioxide emissions, the detection of this gas is garnering increasing attention. Continued advancements in air quality monitoring (AQM) technologies underscore the necessity for low-power gas sensors without sacrificing stability and sensor performance. Polymer-based sensing materials seem to be a very promising prospect for gas sensing at room temperature, offering key improvements over their counterparts, thanks to their lower operating temperature. Polyethylenimine (PEI), a hydrophilic cationic polymer has been studied extensively for its excellent carbon dioxide adsorption properties due to it being rich in amine groups. The use of silicate materials in conjunction with this polymer has been proven to further enhance its sensing capabilities. This study reports on the fabrication of the interdigitated electrode (IDE)-based capacitive sensor, as well as the sensing capabilities facilitated by the PEI-SiO2 nanoparticles (NPs) sensing layer. Specialized gas characterizations were carried out in a controlled environment simulating real-life operating conditions (RH =25%, 50%), and lower sensing temperatures (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${T} = 55~^{\circ }$ </tex-math></inline-formula> C, <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$30~^{\circ }$ </tex-math></inline-formula> C). With CO2 concentrations ranging from 250 to 2000 ppm. Under <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$55~^{\circ }$ </tex-math></inline-formula> C, the response demonstrated an overall capacitance change of about 52% for 2000 ppm of CO2 with a short response and recovery times of about 55 and 45 s, respectively. The sensor also demonstrated good reversibility and stability.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-02-07
DOI
https://doi.org/10.1109/jsen.2025.3537180
Citations
2
Primary Topic
Gas Sensing Nanomaterials and Sensors
Type
article
Field-Weighted Citation Impact
1.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Near-Room-Temperature CO2 Capacitive Sensors Based on Hybrid Polymer Sensitive Materials

A. Souifi, Sébastien Cavalaglio, Riadh Ben Abbes, J.R. Plaussu et al.
2 citations
IEEE Sensors Journal
Gas Sensing Nanomaterials and Sensors
1.46
article

Near-Room-Temperature CO2 Capacitive Sensors Based on Hybrid Polymer Sensitive Materials

A. Souifi, Sébastien Cavalaglio, Riadh Ben Abbes, J.R. Plaussu, B. Salem, S. Monfray, T. Fiorido, Marc Bendahan, A Ghouma, G. Crowin
article en
2 citations

Abstract

Driven by growing concerns over the health hazards linked to carbon dioxide emissions, the detection of this gas is garnering increasing attention. Continued advancements in air quality monitoring (AQM) technologies underscore the necessity for low-power gas sensors without sacrificing stability and sensor performance. Polymer-based sensing materials seem to be a very promising prospect for gas sensing at room temperature, offering key improvements over their counterparts, thanks to their lower operating temperature. Polyethylenimine (PEI), a hydrophilic cationic polymer has been studied extensively for its excellent carbon dioxide adsorption properties due to it being rich in amine groups. The use of silicate materials in conjunction with this polymer has been proven to further enhance its sensing capabilities. This study reports on the fabrication of the interdigitated electrode (IDE)-based capacitive sensor, as well as the sensing capabilities facilitated by the PEI-SiO2 nanoparticles (NPs) sensing layer. Specialized gas characterizations were carried out in a controlled environment simulating real-life operating conditions (RH =25%, 50%), and lower sensing temperatures (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${T} = 55~^{\circ }$ </tex-math></inline-formula> C, <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$30~^{\circ }$ </tex-math></inline-formula> C). With CO2 concentrations ranging from 250 to 2000 ppm. Under <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$55~^{\circ }$ </tex-math></inline-formula> C, the response demonstrated an overall capacitance change of about 52% for 2000 ppm of CO2 with a short response and recovery times of about 55 and 45 s, respectively. The sensor also demonstrated good reversibility and stability.

IEEE Sensors JournalVol. 25(6)
Aix-Marseille Université (FR), STMicroelectronics (France) (FR), Institut des Matériaux, de Microélectronique et des Nanosciences de Provence (FR), Laboratoire des Technologies de la Microélectronique (FR)
Affordable and clean energy
Openalex Percentile: Top 20%
Gas Sensing Nanomaterials and Sensors
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.