Ascending aorta and aortic arch replacement without circulatory arrest

Circulatory arrest is the main method used in surgical interventions for prosthetics of the proximal aorta. However, recently, facts have been discovered that prove the benefits of avoiding circulatory arrest during planned and emergency surgical interventions. We present a clinical case of planned prosthetics of the ascending section and the aortic arch with a Intergard Woven 28 mm multibranch prosthesis without circulatory arrest in conditions of mild hypothermia. The patient was extubated 5 hours after the operation, and was discharged home in satisfactory condition on the 7th day. The rejection of circulatory arrest made it possible to reduce the duration of surgery, the duration of hospitalization and complications associated with hypoperfusion of organs and tissues that occur during cooling of patients.

Authors

Institutions

Publication Details

Journal
Pirogov Russian Journal of Surgery
Published
2025-02-07
DOI
https://doi.org/10.17116/hirurgia2025021119
Citations
1
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
1.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ascending aorta and aortic arch replacement without circulatory arrest

V.A. Sapunov, S. Yu. Boldyrev, S. A. Raff, V.Yu. Ivashchuk et al.
1 citations
Pirogov Russian Journal of Surgery
Aortic Disease and Treatment Approaches
1.52
article

Ascending aorta and aortic arch replacement without circulatory arrest

V.A. Sapunov, S. Yu. Boldyrev, S. A. Raff, V.Yu. Ivashchuk, S.B. Abidzakh, К. О. Барбухатти, P.K. Tyutyunikov, I.V. Tolstykh
article en
1 citations

Abstract

Circulatory arrest is the main method used in surgical interventions for prosthetics of the proximal aorta. However, recently, facts have been discovered that prove the benefits of avoiding circulatory arrest during planned and emergency surgical interventions. We present a clinical case of planned prosthetics of the ascending section and the aortic arch with a Intergard Woven 28 mm multibranch prosthesis without circulatory arrest in conditions of mild hypothermia. The patient was extubated 5 hours after the operation, and was discharged home in satisfactory condition on the 7th day. The rejection of circulatory arrest made it possible to reduce the duration of surgery, the duration of hospitalization and complications associated with hypoperfusion of organs and tissues that occur during cooling of patients.

Pirogov Russian Journal of Surgery(2)
Kuban State Medical University (RU)
Good health and well-being
Openalex Percentile: Top 22%
Aortic Disease and Treatment Approaches
1.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.