Blood pressure in human large cerebral arteries: a feasibility study

The lack of direct measures of brain blood pressure (BBP) has severely restricted understanding of cerebral pressure-flow relationships and their control. We sought to evaluate the feasibility of directly measuring BBP and its pulsatility between the aorta and middle cerebral artery (MCA) during elective endovascular surgical procedures. We report five case studies (four female, 61 ± 13 yr; means ± SD) of patients undergoing cerebrovascular interventional procedures for aneurysm and stenoses, using direct BBP measures with the COMET 2 pressure guidewire system (Boston Scientific). Patients were supine, intubated, and under anesthesia. The sensor wire was inserted via the femoral artery, measuring, as feasible, blood pressure (BP) in the aorta to MCA vascular segments, referenced to the radial artery BP waveform (arterial catheter). Mean arterial pressure varied between the radial (80 ± 18 mmHg), internal carotid artery (ICA; 70 ± 25 mmHg), and MCA (62 ± 29 mmHg), and marked interindividual heterogeneity was observed. Pulse pressure was higher in the radial artery (68 ± 23 mmHg) compared with the intracranial ICA (ICAi; 43 ± 29 mmHg) and MCA (M1; 25 ± 12 mmHg) segments. Direct measures of BBP in humans are feasible in this interventional surgery model. Although limited by the small sample size, the results suggest a heterogenous pattern of change between systemic and brain measures of blood pressure and pulse pressure.<b>NEW & NOTEWORTHY</b> We explored the feasibility of making direct measures of blood pressure in the large arteries at the base of the brain in humans. Measures were made with an optical sensor positioned in the aorta, common carotid, internal carotid artery external to the cranium, internal carotid artery within the cranium, and/or middle cerebral artery (MCA), M1 segment. Measures varied across individuals, as did the pressure gradient from systemic pressures to those in the MCA.

Authors

Institutions

Publication Details

Journal
Journal of Applied Physiology
Published
2025-02-07
DOI
https://doi.org/10.1152/japplphysiol.00825.2024
Citations
1
Primary Topic
Cerebrovascular and Carotid Artery Diseases
Type
article
Field-Weighted Citation Impact
1.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Blood pressure in human large cerebral arteries: a feasibility study

Leena N. Shoemaker, Santiago Ortega‐Gutiérrez, Farah Kamar, Mario Zanaty et al.
1 citations
Journal of Applied Physiology
Cerebrovascular and Carotid Artery Diseases
1.52
article

Blood pressure in human large cerebral arteries: a feasibility study

Leena N. Shoemaker, Santiago Ortega‐Gutiérrez, Farah Kamar, Mario Zanaty, Keith St. Lawrence, J. Kevin Shoemaker, Tyson Matern
article en
1 citations

Abstract

The lack of direct measures of brain blood pressure (BBP) has severely restricted understanding of cerebral pressure-flow relationships and their control. We sought to evaluate the feasibility of directly measuring BBP and its pulsatility between the aorta and middle cerebral artery (MCA) during elective endovascular surgical procedures. We report five case studies (four female, 61 ± 13 yr; means ± SD) of patients undergoing cerebrovascular interventional procedures for aneurysm and stenoses, using direct BBP measures with the COMET 2 pressure guidewire system (Boston Scientific). Patients were supine, intubated, and under anesthesia. The sensor wire was inserted via the femoral artery, measuring, as feasible, blood pressure (BP) in the aorta to MCA vascular segments, referenced to the radial artery BP waveform (arterial catheter). Mean arterial pressure varied between the radial (80 ± 18 mmHg), internal carotid artery (ICA; 70 ± 25 mmHg), and MCA (62 ± 29 mmHg), and marked interindividual heterogeneity was observed. Pulse pressure was higher in the radial artery (68 ± 23 mmHg) compared with the intracranial ICA (ICAi; 43 ± 29 mmHg) and MCA (M1; 25 ± 12 mmHg) segments. Direct measures of BBP in humans are feasible in this interventional surgery model. Although limited by the small sample size, the results suggest a heterogenous pattern of change between systemic and brain measures of blood pressure and pulse pressure.<b>NEW & NOTEWORTHY</b> We explored the feasibility of making direct measures of blood pressure in the large arteries at the base of the brain in humans. Measures were made with an optical sensor positioned in the aorta, common carotid, internal carotid artery external to the cranium, internal carotid artery within the cranium, and/or middle cerebral artery (MCA), M1 segment. Measures varied across individuals, as did the pressure gradient from systemic pressures to those in the MCA.

Journal of Applied PhysiologyVol. 138(3)
SHOWA Medical University (JP), Western University (CA), University of Iowa Hospitals and Clinics (US), University of Iowa Health Care (US)
Heart and Stroke Foundation of Canada, National Institutes of Health, Natural Sciences and Engineering Research Council of Canada
Good health and well-being
Openalex Percentile: Top 22%
Cerebrovascular and Carotid Artery Diseases
1.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.