Use of TOFSim, a LabView-Based Time-of-Flight Mass Spectrometer Simulation, to Model Real Instrument Data

It is demonstrated here that a recently published LabView-based time-of-flight mass spectrometer (TOFMS) simulation program (named TOFSim) can accurately simulate data collected on a commercial Bruker Autoflex III matrix-assisted laser desorption/ionization (MALDI) TOFMS instrument operating in linear mode. Once the instrument distances are determined by matching measured and simulated flight times, it is shown that both overall flight times and peak widths are reproduced for data collected under both focused and slightly defocused conditions. This work confirms that TOFSim can be used not just for training new instrument operators in the principles of TOFMS but, as demonstrated here, to show how changing the voltage applied to grid G1 in the source or the delayed extraction delay time affects the focusing properties of the instrument. In the future we expect that this will also allow users to perform "what-if" experiments to investigate scenarios which may be difficult or impossible to do in a real instrument.

Authors

Institutions

Publication Details

Journal
Journal of the American Society for Mass Spectrometry
Published
2025-02-07
DOI
https://doi.org/10.1021/jasms.4c00406
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Use of TOFSim, a LabView-Based Time-of-Flight Mass Spectrometer Simulation, to Model Real Instrument Data

Kevin G. Owens, Hannah M. Palmer
Journal of the American Society for Mass Spectrometry
Mass Spectrometry Techniques and Applications
article

Use of TOFSim, a LabView-Based Time-of-Flight Mass Spectrometer Simulation, to Model Real Instrument Data

Kevin G. Owens, Hannah M. Palmer
article en

Abstract

It is demonstrated here that a recently published LabView-based time-of-flight mass spectrometer (TOFMS) simulation program (named TOFSim) can accurately simulate data collected on a commercial Bruker Autoflex III matrix-assisted laser desorption/ionization (MALDI) TOFMS instrument operating in linear mode. Once the instrument distances are determined by matching measured and simulated flight times, it is shown that both overall flight times and peak widths are reproduced for data collected under both focused and slightly defocused conditions. This work confirms that TOFSim can be used not just for training new instrument operators in the principles of TOFMS but, as demonstrated here, to show how changing the voltage applied to grid G1 in the source or the delayed extraction delay time affects the focusing properties of the instrument. In the future we expect that this will also allow users to perform "what-if" experiments to investigate scenarios which may be difficult or impossible to do in a real instrument.

Journal of the American Society for Mass SpectrometryVol. 36(3)
Drexel University (US)
Affordable and clean energy
Openalex Percentile: Top 98%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Use of TOFSim, a LabView-Based Time-of-Flight Mass Spectrometer Simulation, to Model Real Instrument Data — Kevin G. Owens, Hannah M. Palmer · Journal of the American Society for Mass Spectrometry (2025) | TGRS Research Map | TGRS