Optimization of Bonner sphere spectrometer design applying Bayesian approach

The design of Bonner Sphere Spectrometer (BSS) was optimized using Bayesian approach for two different measurement purposes in the ISO 8529 neutron standard field of 241Am-Be source as follows: (i) for the best estimation of neutron fluence spectrum and (ii) for the best estimation of neutron ambient dose equivalent, H*(10). As results, two optimal sets of BSS system (with sequential specific diameters) were proposed: (i) for the first problem, an optimal BSS system with a maximum of six different diameters is needed to obtain neutron fluence spectrum with the standard uncertainties in each energy bin as low as reasonably achievable and (ii) for the second problem, if one would just like to achieve the output H*(10) with a standard uncertainty <10%, only two optimal BSS measurements are needed.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2025-01-26
DOI
https://doi.org/10.1093/rpd/ncaf008
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of Bonner sphere spectrometer design applying Bayesian approach

Tadahiro Kurosawa, Ngoc-Thiem Le, Ngoc-Quynh Nguyen
Radiation Protection Dosimetry
Radiation Therapy and Dosimetry
article

Optimization of Bonner sphere spectrometer design applying Bayesian approach

Tadahiro Kurosawa, Ngoc-Thiem Le, Ngoc-Quynh Nguyen
article en

Abstract

The design of Bonner Sphere Spectrometer (BSS) was optimized using Bayesian approach for two different measurement purposes in the ISO 8529 neutron standard field of 241Am-Be source as follows: (i) for the best estimation of neutron fluence spectrum and (ii) for the best estimation of neutron ambient dose equivalent, H*(10). As results, two optimal sets of BSS system (with sequential specific diameters) were proposed: (i) for the first problem, an optimal BSS system with a maximum of six different diameters is needed to obtain neutron fluence spectrum with the standard uncertainties in each energy bin as low as reasonably achievable and (ii) for the second problem, if one would just like to achieve the output H*(10) with a standard uncertainty <10%, only two optimal BSS measurements are needed.

Radiation Protection DosimetryVol. 201(3)
Institute for Nuclear Science and Technology (VN), National Institute of Advanced Industrial Science and Technology (JP)
National Foundation for Science and Technology Development
Affordable and clean energy
Openalex Percentile: Top 97%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimization of Bonner sphere spectrometer design applying Bayesian approach — Tadahiro Kurosawa, Ngoc-Thiem Le, et al. · Radiation Protection Dosimetry (2025) | TGRS Research Map | TGRS