Hybrid discrete and finite element analysis enables fast evaluation of hip joint cartilage mechanical response

Finite element analysis (FEA) is the leading numerical technique for studying joint biomechanics related to the onset and progression of osteoarthritis. However, subject-specific FEA of joint mechanics is a time- and compute-intensive process limiting its clinical applicability. We introduce and evaluate a novel hybrid modelling framework combining discrete element analysis (DEA) and FEA for computationally efficient evaluation of cartilage mechanics in the hip joint. In our approach, the hip joint contact mechanics are first estimated using DEA and subsequently used as input for matching FEA models, substantially reducing model complexity. The cartilage mechanical responses obtained using the hybrid DEA-FEA method were evaluated for subject-specific hip joint geometries from five asymptomatic individuals under loading conditions typical to normal walking gait and compared to conventional FEA in terms of peak intra-tissue mechanical stresses and model run-times. The hybrid DEA-FEA method had a median run-time of 3.6 min per subject (64-core processor, 512 GB RAM) and produced minimum principal (compressive) stress estimates comparable to stresses obtained using conventional FEA models with a median run-time of 96.2 min. On average, the peak compressive stresses obtained using the hybrid DEA-FEA approach were 0.06 MPa (95 % confidence interval: -0.86-0.99) lower than the stresses estimated with conventional FEA. Despite up to 1.4 MPa differences at individual gait time-points, the results indicate that the proposed hybrid DEA-FEA method enables estimation of hip cartilage mechanics in a fraction of time compared to conventional FEA, facilitating implementation in large cohort studies and clinical applications.

Authors

Institutions

Publication Details

Journal
Journal of Biomechanics
Published
2025-02-06
DOI
https://doi.org/10.1016/j.jbiomech.2025.112568
Primary Topic
Hip disorders and treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hybrid discrete and finite element analysis enables fast evaluation of hip joint cartilage mechanical response

Mikko S. Venäläinen, Rami Kristian Korhonen, Jürgen Fripp, ‪Stuart Crozier‬ et al.
Journal of Biomechanics
Hip disorders and treatments
article

Hybrid discrete and finite element analysis enables fast evaluation of hip joint cartilage mechanical response

Mikko S. Venäläinen, Rami Kristian Korhonen, Jürgen Fripp, ‪Stuart Crozier‬, Craig Engstrom, Juha Töyräs, Shekhar S. Chandra, Mao Li
article en

Abstract

Finite element analysis (FEA) is the leading numerical technique for studying joint biomechanics related to the onset and progression of osteoarthritis. However, subject-specific FEA of joint mechanics is a time- and compute-intensive process limiting its clinical applicability. We introduce and evaluate a novel hybrid modelling framework combining discrete element analysis (DEA) and FEA for computationally efficient evaluation of cartilage mechanics in the hip joint. In our approach, the hip joint contact mechanics are first estimated using DEA and subsequently used as input for matching FEA models, substantially reducing model complexity. The cartilage mechanical responses obtained using the hybrid DEA-FEA method were evaluated for subject-specific hip joint geometries from five asymptomatic individuals under loading conditions typical to normal walking gait and compared to conventional FEA in terms of peak intra-tissue mechanical stresses and model run-times. The hybrid DEA-FEA method had a median run-time of 3.6 min per subject (64-core processor, 512 GB RAM) and produced minimum principal (compressive) stress estimates comparable to stresses obtained using conventional FEA models with a median run-time of 96.2 min. On average, the peak compressive stresses obtained using the hybrid DEA-FEA approach were 0.06 MPa (95 % confidence interval: -0.86-0.99) lower than the stresses estimated with conventional FEA. Despite up to 1.4 MPa differences at individual gait time-points, the results indicate that the proposed hybrid DEA-FEA method enables estimation of hip cartilage mechanics in a fraction of time compared to conventional FEA, facilitating implementation in large cohort studies and clinical applications.

Journal of BiomechanicsVol. 182
University of Turku (FI), The University of Queensland (AU), University of Eastern Finland (FI), Turku University Hospital (FI), Kuopio University Hospital (FI), Australian e-Health Research Centre (AU), CSIRO Health and Biosecurity (AU)
Academy of Finland, National Health and Medical Research Council
Zero hunger
Openalex Percentile: Top 96%
Hip disorders and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.