Real world data on digital remote refraction in a healthy population of 14,680 eyes
Refractive errors are the leading cause of preventable visual impairment, to which web-based remote refraction could contribute. We report real-world 2021-2022 data of the underlying algorithm and validated these to conventional prescriptions among healthy individuals (high visual acuity and satisfactied current refraction). Participants were 18-45 years with a spherical (S) error between -3.50 + 2.00S to -2.00 Diopter Cylinder (DC), reported as Spherical Equivalent (SEQ) in mean differences and 95% Limits of agreement. Consecutive measurements (n = 14,680) were assessed of which n = 6386 selected for validation. The mean difference was 0.01D(SD 0.69) and -0.73D(SD 0.92) for myopes and hyperopes respectively. This algorithm shows variation, nonetheless, 67% and 82% of myopes were within ±0.5 and ±0.75D. The test underestimates hyperopes (34% and 50% within ±0.5D and ±0.75D) and had inconsistencies distinguishing hyperopia. This proof-of-concept shows home testing has the potency to increase accessibility to care by delivering a valuable alternative for uncomplicated refractive assessments.
Authors
- Robert P. L. Wisse (ORCID: https://orcid.org/0000-0002-2844-9868)
- Gerko Vink (ORCID: https://orcid.org/0000-0001-9767-1924)
- Laurence E. Frank (ORCID: https://orcid.org/0000-0002-4075-8129)
- Casper van der Zee
- Marc B. Muijzer (ORCID: https://orcid.org/0000-0002-3341-8302)
- H. Jamal (ORCID: https://orcid.org/0009-0003-1179-0175)
Institutions
- Utrecht University (NL)
- University Medical Center Utrecht (NL)
Publication Details
- Journal
- npj Digital Medicine
- Published
- 2025-02-06
- DOI
- https://doi.org/10.1038/s41746-025-01453-0
- Citations
- 2
- Primary Topic
- Ophthalmology and Visual Impairment Studies
- Type
- article
- Field-Weighted Citation Impact
- 2.71
Funders
- Universitair Medisch Centrum Utrecht