Development and Degradation Study of PLA‐Based Medical Implant Markers for Magnetic Particle Imaging

Magnetic particle imaging (MPI) is a promising imaging modality nearing clinical introduction. MPI's tracer-based principle allows for highly sensitive background-free imaging. Potential clinical applications include cardiovascular imaging and endovascular interventions. In principle, medical instruments are invisible in MPI due to the missing signal generation. Therefore, permanent marking technologies have been introduced. Additionally, temporary markers are of interest for follow-up examinations after stent implantation to prevent artifacts during postinterventional stent lumen quantification. Consequently, medical instrument markers for MPI, based on biodegradable polylactic acid (PLA) and superparamagnetic iron-oxide nanoparticles (SPIONs), are developed in this study. To investigate the markers, signal characteristics and degradation over time are studied for 28 d in a water bath at 37 °C. The samples are analyzed using a scale, micro-CT, microscopy, magnetic particle spectroscopy (MPS), MPI, and vibrating sample magnetometry (VSM). A continuous mass decrease is detected (≈90% after 28 d), while MPS and MPI data show no loss of signal. VSM confirms that the markers' mass reduction can be accounted for the degradation of PLA, while the SPIONs hardly detach from the coating. The introduced marking technology, with its degradation characteristics and signal behavior, is the basis for a variety of anticipated medical application scenarios.

Authors

Institutions

Publication Details

Journal
Macromolecular Bioscience
Published
2025-02-06
DOI
https://doi.org/10.1002/mabi.202400495
Citations
3
Primary Topic
Characterization and Applications of Magnetic Nanoparticles
Type
article
Field-Weighted Citation Impact
2.02

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Degradation Study of PLA‐Based Medical Implant Markers for Magnetic Particle Imaging

Thomas Friedrich, Mandy Ahlborg, M Buhné, Malte Maria Sieren et al.
3 citations
Macromolecular Bioscience
Characterization and Applications of Magnetic Nanoparticles
2.02
article

Development and Degradation Study of PLA‐Based Medical Implant Markers for Magnetic Particle Imaging

Thomas Friedrich, Mandy Ahlborg, M Buhné, Malte Maria Sieren, Kerstin Lüdtke‐Buzug, Jörg Barkhausen, David Melenberg, Justin Ackers, Roman Kloeckner, Thorsten M. Buzug, Franz Wegner, Maximilian Wattenberg, Liana Mirzojan, Johann Christopher Engster, Ankit Malhotra, Patrick N. Elfers
article en
3 citations

Abstract

Magnetic particle imaging (MPI) is a promising imaging modality nearing clinical introduction. MPI's tracer-based principle allows for highly sensitive background-free imaging. Potential clinical applications include cardiovascular imaging and endovascular interventions. In principle, medical instruments are invisible in MPI due to the missing signal generation. Therefore, permanent marking technologies have been introduced. Additionally, temporary markers are of interest for follow-up examinations after stent implantation to prevent artifacts during postinterventional stent lumen quantification. Consequently, medical instrument markers for MPI, based on biodegradable polylactic acid (PLA) and superparamagnetic iron-oxide nanoparticles (SPIONs), are developed in this study. To investigate the markers, signal characteristics and degradation over time are studied for 28 d in a water bath at 37 °C. The samples are analyzed using a scale, micro-CT, microscopy, magnetic particle spectroscopy (MPS), MPI, and vibrating sample magnetometry (VSM). A continuous mass decrease is detected (≈90% after 28 d), while MPS and MPI data show no loss of signal. VSM confirms that the markers' mass reduction can be accounted for the degradation of PLA, while the SPIONs hardly detach from the coating. The introduced marking technology, with its degradation characteristics and signal behavior, is the basis for a variety of anticipated medical application scenarios.

Macromolecular BioscienceVol. 25(4)
University Hospital Schleswig-Holstein (DE), Fraunhofer-Einrichtung für Individualisierte Medizintechnik (DE), University of Lübeck (DE)
Universität zu Lübeck
Clean water and sanitation
Openalex Percentile: Top 16%
Characterization and Applications of Magnetic Nanoparticles
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development and Degradation Study of PLA‐Based Medical Implant Markers for Magnetic Particle Imaging — Thomas Friedrich, Mandy Ahlborg, et al. · Macromolecular Bioscience (2025) | TGRS Research Map | TGRS