Evaluation of the Seismic Performance of a High-Rise Building in Lima, Peru, Using the FEMA 440 and SEOAC Methodologies

This article develops two three-dimensional models: one for designing an 18-story building, considering the E030 and E060 norms of Peru, and a second nonlinear model aimed at estimating the lateral capacity of the structure through nonlinear static analysis and verification of seismic performance. It highlights the prevalence of informal structures in Peru, which lack a performance-based design methodology. In this context, relying solely on elastic design may be insufficient, especially for tall buildings. A "seismic gap" is identified, referring to the discrepancy between current design practices and the actual seismic demands that structures may face, raising concerns about the vulnerability of existing and future structures to a potential earthquake. The nonlinear static analysis showed that the 18-story structure reached a maximum base shear of 1752 tons and a maximum displacement of approximately 53 cm in the X direction, and similarly, a maximum base shear of 1538 tons and a maximum displacement of 51 cm in the Y direction.

Authors

Institutions

Publication Details

Journal
Engineering innovations
Published
2025-02-06
DOI
https://doi.org/10.4028/p-a1nwd6
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the Seismic Performance of a High-Rise Building in Lima, Peru, Using the FEMA 440 and SEOAC Methodologies

Rick M. Delgadillo, Joan R. Casas, Andrius Norman Lucana
Engineering innovations
Seismic Performance and Analysis
article

Evaluation of the Seismic Performance of a High-Rise Building in Lima, Peru, Using the FEMA 440 and SEOAC Methodologies

Rick M. Delgadillo, Joan R. Casas, Andrius Norman Lucana
article en

Abstract

This article develops two three-dimensional models: one for designing an 18-story building, considering the E030 and E060 norms of Peru, and a second nonlinear model aimed at estimating the lateral capacity of the structure through nonlinear static analysis and verification of seismic performance. It highlights the prevalence of informal structures in Peru, which lack a performance-based design methodology. In this context, relying solely on elastic design may be insufficient, especially for tall buildings. A "seismic gap" is identified, referring to the discrepancy between current design practices and the actual seismic demands that structures may face, raising concerns about the vulnerability of existing and future structures to a potential earthquake. The nonlinear static analysis showed that the 18-story structure reached a maximum base shear of 1752 tons and a maximum displacement of approximately 53 cm in the X direction, and similarly, a maximum base shear of 1538 tons and a maximum displacement of 51 cm in the Y direction.

Engineering innovationsVol. 13
Peruvian University of Applied Sciences (PE), Universitat Politècnica de Catalunya (ES)
Openalex Percentile: Top 97%
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of the Seismic Performance of a High-Rise Building in Lima, Peru, Using the FEMA 440 and SEOAC Methodologies — Rick M. Delgadillo, Joan R. Casas, et al. · Engineering innovations (2025) | TGRS Research Map | TGRS