Neonatal Electroencephalogram Recording with a Dry Electrode Cap: A Feasibility Study

This study investigates the feasibility of a dry electrode cap design for neonatal electroencephalogram (EEG) recordings. Recordings on a phantom and a real infant are compared between a novel dry electrode cap and a clinically used gel-based electrode cap. The phantom recordings included measuring both the electrode contact force and the signal quality during still and respiration-like head motion. The real infant recordings were assessed for the EEG signals' spectral characteristics, including powerline interference. Compared to gel-based caps, the dry caps showed a largely comparable skin force, an expectedly greater sensitivity to motion-induced artifacts, and a slightly lower powerline interference. Recordings on the real infant showed no significant skin marks after using the dry electrode, and the spectral compositions were comparable between dry- and gel-based electrode caps. These findings suggest that neonatal EEG recordings with a dry electrode cap are technically feasible, but movement-related artifacts, such as respiration in a supine lying infant, may challenge long-term recordings of spontaneous EEG activity. Yet, the ease of use of dry electrode caps calls for future studies to define the optimal use case in neonatal recordings.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-02-05
DOI
https://doi.org/10.3390/s25030966
Citations
3
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
4.29
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Neonatal Electroencephalogram Recording with a Dry Electrode Cap: A Feasibility Study

Sampsa Vanhatalo, Indhika Fauzhan Warsito, Jens Haueisen, Patrique Fiedler et al.
3 citations
Sensors
EEG and Brain-Computer Interfaces
4.29
article

Neonatal Electroencephalogram Recording with a Dry Electrode Cap: A Feasibility Study

Sampsa Vanhatalo, Indhika Fauzhan Warsito, Jens Haueisen, Patrique Fiedler, Amirreza Asayesh
article en
3 citations

Abstract

This study investigates the feasibility of a dry electrode cap design for neonatal electroencephalogram (EEG) recordings. Recordings on a phantom and a real infant are compared between a novel dry electrode cap and a clinically used gel-based electrode cap. The phantom recordings included measuring both the electrode contact force and the signal quality during still and respiration-like head motion. The real infant recordings were assessed for the EEG signals' spectral characteristics, including powerline interference. Compared to gel-based caps, the dry caps showed a largely comparable skin force, an expectedly greater sensitivity to motion-induced artifacts, and a slightly lower powerline interference. Recordings on the real infant showed no significant skin marks after using the dry electrode, and the spectral compositions were comparable between dry- and gel-based electrode caps. These findings suggest that neonatal EEG recordings with a dry electrode cap are technically feasible, but movement-related artifacts, such as respiration in a supine lying infant, may challenge long-term recordings of spontaneous EEG activity. Yet, the ease of use of dry electrode caps calls for future studies to define the optimal use case in neonatal recordings.

SensorsVol. 25(3)
Technische Universität Ilmenau (DE), University of Helsinki (FI), Helsinki University Hospital (FI), Jena University Hospital (DE)
Openalex Percentile: Top 7%
EEG and Brain-Computer Interfaces
4.29
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Neonatal Electroencephalogram Recording with a Dry Electrode Cap: A Feasibility Study — Sampsa Vanhatalo, Indhika Fauzhan Warsito, et al. · Sensors (2025) | TGRS Research Map | TGRS