Semi-preparative on-line supercritical fluid extraction-supercritical fluid chromatography for solid-state injection and purification

• Investigation of ibuprofen solubility changes in a subcritical mobile phase. • Utilization of an extraction oven for solid-state injection. • Examination of the impact of co-solvent ratio on solid-state injection loadability. • Study of the effects of extraction duration on solid-state injection-loadability. • Application of the methodology to process samples up to several grams. Thanks to the versatility and low viscosity of sub/supercritical fluids, supercritical fluid extraction (SFE) and supercritical fluid chromatography (SFC) are attractive to extract and separate molecules in a quick and efficient way. By coupling both techniques, on-line SFE-SFC becomes even more versatile and can extract, separate, and detect molecules in a single approach. When used at semi-preparative (semi-prep.) scale, on-line SFE-SFC can also be an interesting tool to perform solid-state injection and simplify sample pretreatment before purification. The aim of this publication is to examine the possibilities offered by semi-prep. on-line SFE-SFC for solid-state injection and determine the key parameters for method development, using ibuprofen as a case study. First, solubility changes of ibuprofen in a pressurized carbon dioxide (CO 2 )/methanol mixture were investigated, revealing a favorable solubility at 20 % of co-solvent. Then, an SFC method was developed at analytical scale and scaled up to semi-prep. SFC. This method allowed the separation of ibuprofen from structurally related compounds in less than 3 min, using a Shim-pack UC PolyVP column and 30 % of MeOH in pressurized CO 2 . After that, the effect of co-solvent ratio and extraction duration on semi-prep. on-line SFE-SFC solid-state injection was investigated. With an appropriate static extraction using 20 % of co-solvent for 1 min followed by a dynamic extraction with 5 % of co-solvent over 4 min, it was possible to inject and purify 500 mg of solid-state ibuprofen in 10 min. Finally, the methodology was applied to 2.5 g of sample, demonstrating its suitability for larger solid-state injection.

Authors

Institutions

Publication Details

Journal
Journal of Chromatography Open
Published
2025-02-06
DOI
https://doi.org/10.1016/j.jcoa.2025.100206
Citations
1
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.76
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Semi-preparative on-line supercritical fluid extraction-supercritical fluid chromatography for solid-state injection and purification

Yusuke Masuda, Quentin Gros, H. Terada, Yoshiyuki Watabe
1 citations
Journal of Chromatography Open
Analytical Chemistry and Chromatography
0.76
article

Semi-preparative on-line supercritical fluid extraction-supercritical fluid chromatography for solid-state injection and purification

Yusuke Masuda, Quentin Gros, H. Terada, Yoshiyuki Watabe
article en
1 citations

Abstract

• Investigation of ibuprofen solubility changes in a subcritical mobile phase. • Utilization of an extraction oven for solid-state injection. • Examination of the impact of co-solvent ratio on solid-state injection loadability. • Study of the effects of extraction duration on solid-state injection-loadability. • Application of the methodology to process samples up to several grams. Thanks to the versatility and low viscosity of sub/supercritical fluids, supercritical fluid extraction (SFE) and supercritical fluid chromatography (SFC) are attractive to extract and separate molecules in a quick and efficient way. By coupling both techniques, on-line SFE-SFC becomes even more versatile and can extract, separate, and detect molecules in a single approach. When used at semi-preparative (semi-prep.) scale, on-line SFE-SFC can also be an interesting tool to perform solid-state injection and simplify sample pretreatment before purification. The aim of this publication is to examine the possibilities offered by semi-prep. on-line SFE-SFC for solid-state injection and determine the key parameters for method development, using ibuprofen as a case study. First, solubility changes of ibuprofen in a pressurized carbon dioxide (CO 2 )/methanol mixture were investigated, revealing a favorable solubility at 20 % of co-solvent. Then, an SFC method was developed at analytical scale and scaled up to semi-prep. SFC. This method allowed the separation of ibuprofen from structurally related compounds in less than 3 min, using a Shim-pack UC PolyVP column and 30 % of MeOH in pressurized CO 2 . After that, the effect of co-solvent ratio and extraction duration on semi-prep. on-line SFE-SFC solid-state injection was investigated. With an appropriate static extraction using 20 % of co-solvent for 1 min followed by a dynamic extraction with 5 % of co-solvent over 4 min, it was possible to inject and purify 500 mg of solid-state ibuprofen in 10 min. Finally, the methodology was applied to 2.5 g of sample, demonstrating its suitability for larger solid-state injection.

Journal of Chromatography OpenVol. 7
Shimadzu (Japan) (JP)
Openalex Percentile: Top 35%
Analytical Chemistry and Chromatography
0.76
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.