Minimization of Control Error and Frequency variation in Two Area based Load Frequency Control using GA Tuned Fractional PI<sup>λ</sup>D<sup>μ</sup> Controller by Reducing Integral Absolute based Error

In order to provide adequate, dependable, highquality electric power, one of the most important aspects of power system management and control is automatic generation control, sometimes referred to as load frequency control. A generator’s output power is adjusted by the feedback control system AGC to maintain a defined frequency. Control schemes are necessary for efficient and economical handling of all aspects of power dynamics. Since current LFC system parameters are frequently adjusted using trial-and-error methods, traditional approaches, and experiences, they are unable to deliver sufficient dynamic performance across a wide range of operating situations and load scenarios. In the present work, the influence of performance indice Integral Absolute error is mitigated by employing Genetic Optimization tuned controllers to evaluate and exhibit the response for a Two area system with variations in load and frequency. PID controllers and PID controllers with fractional orders is utilized to migitate the error. A comparison between the two tuned controllers and the simulation results is shown.

Authors

Publication Details

Published
2024-11-21
DOI
https://doi.org/10.1109/ic-sit63503.2024.10862535
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Minimization of Control Error and Frequency variation in Two Area based Load Frequency Control using GA Tuned Fractional PIλDμ Controller by Reducing Integral Absolute based Error

A. Sakthivel, A.S. Anitha Nair
Frequency Control in Power Systems
article

Minimization of Control Error and Frequency variation in Two Area based Load Frequency Control using GA Tuned Fractional PIλDμ Controller by Reducing Integral Absolute based Error

A. Sakthivel, A.S. Anitha Nair
article en

Abstract

In order to provide adequate, dependable, highquality electric power, one of the most important aspects of power system management and control is automatic generation control, sometimes referred to as load frequency control. A generator’s output power is adjusted by the feedback control system AGC to maintain a defined frequency. Control schemes are necessary for efficient and economical handling of all aspects of power dynamics. Since current LFC system parameters are frequently adjusted using trial-and-error methods, traditional approaches, and experiences, they are unable to deliver sufficient dynamic performance across a wide range of operating situations and load scenarios. In the present work, the influence of performance indice Integral Absolute error is mitigated by employing Genetic Optimization tuned controllers to evaluate and exhibit the response for a Two area system with variations in load and frequency. PID controllers and PID controllers with fractional orders is utilized to migitate the error. A comparison between the two tuned controllers and the simulation results is shown.

Affordable and clean energy
Openalex Percentile: Top 75%
Frequency Control in Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.