An Adaptive AFE Circuit to Minimize the Zero-Flow Error in Transit-Time Ultrasonic Water Flowmeter

This paper presents an adaptive analog front end (AFE) circuit for ultrasonic water flowmeter application, including a programmable gain amplifier (PGA) and a low delay dispersion comparator (LDD-CMP). The gain of the PGA is adaptively controlled by a peak detector to minimize the input amplitude variation of the comparator. As to the LDD-CMP, an adaptive current regulating circuit is designed for the conventional two-stage open-loop comparator to reduce the propagation delay dispersion caused by the different input overdrive. The proposed AFE has been fabricated in a $180-\mathrm{nm}$ CMOS technology, and the measurement results show that the zero-flow error of the ultrasonic flowmeter ASIC with the proposed AFE is only $6.3 \%$ of that of the one with a conventional comparator, and $6.2 \%$ of the commercial product TDC-GP22, with input frequency at 1 MHz.

Authors

Institutions

Publication Details

Published
2024-10-25
DOI
https://doi.org/10.1109/icta64028.2024.10860363
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Adaptive AFE Circuit to Minimize the Zero-Flow Error in Transit-Time Ultrasonic Water Flowmeter

Kaiyou Li, Jianping Guo, Zijun Huang
Flow Measurement and Analysis
article

An Adaptive AFE Circuit to Minimize the Zero-Flow Error in Transit-Time Ultrasonic Water Flowmeter

Kaiyou Li, Jianping Guo, Zijun Huang
article en

Abstract

This paper presents an adaptive analog front end (AFE) circuit for ultrasonic water flowmeter application, including a programmable gain amplifier (PGA) and a low delay dispersion comparator (LDD-CMP). The gain of the PGA is adaptively controlled by a peak detector to minimize the input amplitude variation of the comparator. As to the LDD-CMP, an adaptive current regulating circuit is designed for the conventional two-stage open-loop comparator to reduce the propagation delay dispersion caused by the different input overdrive. The proposed AFE has been fabricated in a $180-\mathrm{nm}$ CMOS technology, and the measurement results show that the zero-flow error of the ultrasonic flowmeter ASIC with the proposed AFE is only $6.3 \%$ of that of the one with a conventional comparator, and $6.2 \%$ of the commercial product TDC-GP22, with input frequency at 1 MHz.

Sun Yat-sen University (CN)
Clean water and sanitation
Openalex Percentile: Top 70%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An Adaptive AFE Circuit to Minimize the Zero-Flow Error in Transit-Time Ultrasonic Water Flowmeter — Kaiyou Li, Jianping Guo, et al. · (2024) | TGRS Research Map | TGRS