Computational modeling of bone allograft reconstruction following femoral shaft tumor resection: Investigating the impact of supplementary plate fixation
PMMA augmentation reduces IFM and sliding distances, enhancing rigidity, particularly in the distal area. Supplementary plate fixation decreases IFM distances in the proximal area but increases sliding distances in the same region. Variants III and IV demonstrate lower IFM and sliding distances in the distal area overall. Variant III shows very low sliding distances in both distal and proximal areas. Variant IV combines improved firmness with slightly higher stress levels.
Authors
- Tomáš Tomáš (ORCID: https://orcid.org/0000-0002-5501-2143)
- Petr Marcián (ORCID: https://orcid.org/0000-0002-9458-9690)
- Michal Mahdal (ORCID: https://orcid.org/0000-0002-2136-9136)
- Petr Boháč (ORCID: https://orcid.org/0009-0006-8718-101X)
- Tomáš Návrat (ORCID: https://orcid.org/0000-0003-2772-3551)
- Vasileios Apostolopoulos (ORCID: https://orcid.org/0000-0001-9719-4769)
Institutions
- Masaryk University (CZ)
- St. Anne's University Hospital Brno (CZ)
Publication Details
- Journal
- PLoS ONE
- Published
- 2025-02-06
- DOI
- https://doi.org/10.1371/journal.pone.0316719
- Primary Topic
- Orthopaedic implants and arthroplasty
- Type
- article
- Field-Weighted Citation Impact
- 0.00