Robotic Assistance is Associated With No Intraoperative Fluoroscopy or Radiation Exposure During Direct Anterior Total Hip Arthroplasty

In this cadaver-based study, the use of a CT-based RA-THA DAA eliminated the need for intraoperative fluoroscopy, removing the concern of radiation exposure to the surgeon and surgical staff. The CT-based RA-THA DAA does require a preoperative CT scan of the patient; however, the radiation dosage to the patient was equivalent to 8.7 intraoperative fluoroscopy shots. As more surgeons, patients, and surgical staff are exposed to an increasing number of orthopaedic procedures that require ionizing radiation to generate images, such as fluoroscopy and CT, it is important to consider the radiation dosage for all individuals and understand the positives and negatives of each treatment. We must consider the overall long-term health impacts of continuous fluoroscopy vs a one-time CT scan. This is of particular importance to the surgeon and surgical staff who may be exposed to cumulative doses during multiple procedures.

Authors

Institutions

Publication Details

Journal
Arthroplasty Today
Published
2025-02-06
DOI
https://doi.org/10.1016/j.artd.2025.101617
Citations
3
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
6.02

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Robotic Assistance is Associated With No Intraoperative Fluoroscopy or Radiation Exposure During Direct Anterior Total Hip Arthroplasty

Benjamin M. Frye, Joseph P. Nessler, Sean B. Sequeira, Alan Brett et al.
3 citations
Arthroplasty Today
Orthopaedic implants and arthroplasty
6.02
article

Robotic Assistance is Associated With No Intraoperative Fluoroscopy or Radiation Exposure During Direct Anterior Total Hip Arthroplasty

Benjamin M. Frye, Joseph P. Nessler, Sean B. Sequeira, Alan Brett, Michael A. Mont
article en
3 citations

Abstract

In this cadaver-based study, the use of a CT-based RA-THA DAA eliminated the need for intraoperative fluoroscopy, removing the concern of radiation exposure to the surgeon and surgical staff. The CT-based RA-THA DAA does require a preoperative CT scan of the patient; however, the radiation dosage to the patient was equivalent to 8.7 intraoperative fluoroscopy shots. As more surgeons, patients, and surgical staff are exposed to an increasing number of orthopaedic procedures that require ionizing radiation to generate images, such as fluoroscopy and CT, it is important to consider the radiation dosage for all individuals and understand the positives and negatives of each treatment. We must consider the overall long-term health impacts of continuous fluoroscopy vs a one-time CT scan. This is of particular importance to the surgeon and surgical staff who may be exposed to cumulative doses during multiple procedures.

Arthroplasty TodayVol. 32
West Virginia University (US), Sinai Hospital (US), MedStar Union Memorial Hospital (US), St. Cloud Orthopedic Associates (US), Stryker (United States) (US)
Stryker
Openalex Percentile: Top 5%
Orthopaedic implants and arthroplasty
6.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.