An ingestible bioimpedance sensing device for wireless monitoring of epithelial barriers

Existing gastrointestinal (GI) diagnostic tools are unable to non-invasively monitor mucosal tight junction integrity in vivo beyond the esophagus. In the GI tract, local inflammatory processes induce alterations in tight junction proteins, enhancing paracellular ion permeability. Although transepithelial electrical resistance (TEER) may be used in the laboratory to assess mucosal barrier integrity, there are no existing methodologies for characterizing tight junction dilation in vivo. Addressing this technology gap, intraluminal bioimpedance sensing may be employed as a localized, non-invasive surrogate to TEER electrodes used in cell cultures. Thus far, bioimpedance has only been implemented in esophagogastroduodenoscopy (EGD) due to the need for external electronics connections. In this work, we develop a novel, noise-resilient Bluetooth-enabled ingestible device for the continuous, non-invasive measurement of intestinal mucosal "leakiness." As a proof-of-concept, we validate wireless impedance readout on excised porcine tissues in motion. Through an animal study, we demonstrate how the device exhibits altered impedance response to tight junction dilation induced on mice colonic tissue through calcium-chelator exposure. Device measurements are validated using standard benchtop methods for assessing mucosal permeability.

Authors

Institutions

Publication Details

Journal
Microsystems & Nanoengineering
Published
2025-02-07
DOI
https://doi.org/10.1038/s41378-025-00877-8
Citations
7
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
5.11

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An ingestible bioimpedance sensing device for wireless monitoring of epithelial barriers

Pankaj J. Pasricha, Younggeon Jin, Justin M. Stine, Luke A. Beardslee et al.
7 citations
Microsystems & Nanoengineering
Electrical and Bioimpedance Tomography
5.11
article

An ingestible bioimpedance sensing device for wireless monitoring of epithelial barriers

Pankaj J. Pasricha, Younggeon Jin, Justin M. Stine, Luke A. Beardslee, Bill Holt, Reza Ghodssi, Hammed Ayansola
article en
7 citations

Abstract

Existing gastrointestinal (GI) diagnostic tools are unable to non-invasively monitor mucosal tight junction integrity in vivo beyond the esophagus. In the GI tract, local inflammatory processes induce alterations in tight junction proteins, enhancing paracellular ion permeability. Although transepithelial electrical resistance (TEER) may be used in the laboratory to assess mucosal barrier integrity, there are no existing methodologies for characterizing tight junction dilation in vivo. Addressing this technology gap, intraluminal bioimpedance sensing may be employed as a localized, non-invasive surrogate to TEER electrodes used in cell cultures. Thus far, bioimpedance has only been implemented in esophagogastroduodenoscopy (EGD) due to the need for external electronics connections. In this work, we develop a novel, noise-resilient Bluetooth-enabled ingestible device for the continuous, non-invasive measurement of intestinal mucosal "leakiness." As a proof-of-concept, we validate wireless impedance readout on excised porcine tissues in motion. Through an animal study, we demonstrate how the device exhibits altered impedance response to tight junction dilation induced on mice colonic tissue through calcium-chelator exposure. Device measurements are validated using standard benchtop methods for assessing mucosal permeability.

Microsystems & NanoengineeringVol. 11(1)
Mayo Clinic Hospital (US), Matrix Research (United States) (US), University of Maryland, College Park (US)
National Science Foundation, Division of Electrical, Communications and Cyber Systems
Openalex Percentile: Top 5%
Electrical and Bioimpedance Tomography
5.11
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.