Characterization of electron density and ionization of a uranium laser produced plasma using laser absorption spectroscopy

High-resolution tunable laser spectroscopy is used to measure time-resolved absorption spectra for ten neutral uranium transitions and six singly-ionized transitions in a laser produced plasma. Spectral lineshapes are analyzed to determine temporal variations in ion and neutral total column densities, excitation temperatures, kinetic temperatures, and collisional broadening effects as the plasma cools. Comparison of ion to neutral column densities shows a ratio greater than 10 at times < 15 μs after plasma onset, with the ratio not reaching unity until 50 μs. Spectral lineshapes are analyzed to separate Stark and van der Waals contributions to collisional broadening, from which electron densities are determined and found to decrease from ∼ 10 15 –10 13 cm −3 over times from 4–25 μs. Using absorption spectroscopy to determine charge properties and electron density over these time scales and at low magnitudes provides valuable insight into plasma properties not obtainable using conventional emission spectroscopy. Comparisons between ion and neutral densities, excitation temperatures, kinetic temperatures, and electron densities could indicate potential deviations from local thermodynamic equilibrium and Saha ionization predictions. • High resolution spectral measurements of U neutral and ionic transitions employing tunable laser absorption spectroscopy . • Spectral lineshapes of uranium, and spectral fitting to extract plasma parameters as a function of time. • Measured electron density from 10 15 –10 13 cm −3 , at times later than possible with emission spectroscopy. • Assessments of ionization ratios, excitation temperatures, kinetic temperatures, and electron densities revealed potential deviations from LTE.

Authors

Institutions

Publication Details

Journal
Spectrochimica Acta Part B Atomic Spectroscopy
Published
2025-02-07
DOI
https://doi.org/10.1016/j.sab.2025.107142
Citations
3
Primary Topic
Laser-induced spectroscopy and plasma
Type
article
Field-Weighted Citation Impact
2.59
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterization of electron density and ionization of a uranium laser produced plasma using laser absorption spectroscopy

Mark C. Phillips, Mathew P. Polek, Ryland Gerald Wala, R. Jason Jones et al.
3 citations
Spectrochimica Acta Part B Atomic Spectroscopy
Laser-induced spectroscopy and plasma
2.59
article

Characterization of electron density and ionization of a uranium laser produced plasma using laser absorption spectroscopy

Mark C. Phillips, Mathew P. Polek, Ryland Gerald Wala, R. Jason Jones, S. S. Harilal
article en
3 citations

Abstract

High-resolution tunable laser spectroscopy is used to measure time-resolved absorption spectra for ten neutral uranium transitions and six singly-ionized transitions in a laser produced plasma. Spectral lineshapes are analyzed to determine temporal variations in ion and neutral total column densities, excitation temperatures, kinetic temperatures, and collisional broadening effects as the plasma cools. Comparison of ion to neutral column densities shows a ratio greater than 10 at times < 15 μs after plasma onset, with the ratio not reaching unity until 50 μs. Spectral lineshapes are analyzed to separate Stark and van der Waals contributions to collisional broadening, from which electron densities are determined and found to decrease from ∼ 10 15 –10 13 cm −3 over times from 4–25 μs. Using absorption spectroscopy to determine charge properties and electron density over these time scales and at low magnitudes provides valuable insight into plasma properties not obtainable using conventional emission spectroscopy. Comparisons between ion and neutral densities, excitation temperatures, kinetic temperatures, and electron densities could indicate potential deviations from local thermodynamic equilibrium and Saha ionization predictions. • High resolution spectral measurements of U neutral and ionic transitions employing tunable laser absorption spectroscopy . • Spectral lineshapes of uranium, and spectral fitting to extract plasma parameters as a function of time. • Measured electron density from 10 15 –10 13 cm −3 , at times later than possible with emission spectroscopy. • Assessments of ionization ratios, excitation temperatures, kinetic temperatures, and electron densities revealed potential deviations from LTE.

Spectrochimica Acta Part B Atomic SpectroscopyVol. 227
University of Arizona (US), Pacific Northwest National Laboratory (US), University of California San Diego (US)
Openalex Percentile: Top 13%
Laser-induced spectroscopy and plasma
2.59
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.