Is there a need for a CT scan of the pancreatic phase? A perfusion and simulation study of the pancreas, an HCC, and the kidney cortex

To explore the peak enhancement time of a hepatocellular carcinoma, the pancreas, and the kidney cortex and its determinants.We obtained a time enhancement curve from the perfusion CT scans of 11 advanced HCC patients (40 volumes at 1.25 s time interval, slab slice 90 mm, bolus of 50 ml of iodinated contrast agent, 350 g iodine/ml, flow 5 ml/s). Small regions of interest were drawn on the abdominal aorta, the HCC, the cortex of the right kidney, and on the pancreas. The behavior of the contrast agent in the capillary and in the surrounding tissue was further explored with a finite element model.The peak enhancement time of the pancreas did not differ from that of the HCC (10±3 vs. 11±4 s, p=0.9), while the peak enhancement time of the kidney tended to be a few seconds earlier (8±1 s, p=0.082 vs. pancreas and p=0.069 vs. kidney). Simulation showed that the time span in which the tissue enhancement remained within 10% of its peak value was similar across all capillary densities and ranged between 26-38 s for a capillary density of 80 per mm to 30-60 s for a capillary density of 10.The plateau tissue enhancement clinically acquired in the "late arterial phase" should be adequate both for the detection of hypervascular liver lesions such as HCCs and for obtaining peak pancreatic enhancement to detect hypovascular lesions. · The peak tissue enhancement time of an HCC, the pancreas, and the kidney cortex is similar. · The tissue peak enhancement time in the arterial phase is at the end of bolus transit. · Simulation shows that tissue enhancement peak time is a function of capillary density. · Cressoni M, Cadringher P, Colarieti A et al. Is there a need for a CT scan of the pancreatic phase? A perfusion and simulation study of the pancreas, an HCC, and the kidney cortex. Rofo 2025; 197: 1405-1415.

Authors

Institutions

Publication Details

Journal
RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Published
2025-02-06
DOI
https://doi.org/10.1055/a-2516-3176
Citations
2
Primary Topic
MRI in cancer diagnosis
Type
article
Field-Weighted Citation Impact
2.72
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Is there a need for a CT scan of the pancreatic phase? A perfusion and simulation study of the pancreas, an HCC, and the kidney cortex

Francesco Sardanelli, Federico Ambrogi, Paolo Cadringher, Anna Colarieti et al.
2 citations
RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
MRI in cancer diagnosis
2.72
article

Is there a need for a CT scan of the pancreatic phase? A perfusion and simulation study of the pancreas, an HCC, and the kidney cortex

Francesco Sardanelli, Federico Ambrogi, Paolo Cadringher, Anna Colarieti, Davide Ippolito, Andrea Cozzi, Moreno Zanardo, Fatemeh Darvizeh, Massimo Cressoni, Claudio S. Cinà
article en
2 citations

Abstract

To explore the peak enhancement time of a hepatocellular carcinoma, the pancreas, and the kidney cortex and its determinants.We obtained a time enhancement curve from the perfusion CT scans of 11 advanced HCC patients (40 volumes at 1.25 s time interval, slab slice 90 mm, bolus of 50 ml of iodinated contrast agent, 350 g iodine/ml, flow 5 ml/s). Small regions of interest were drawn on the abdominal aorta, the HCC, the cortex of the right kidney, and on the pancreas. The behavior of the contrast agent in the capillary and in the surrounding tissue was further explored with a finite element model.The peak enhancement time of the pancreas did not differ from that of the HCC (10±3 vs. 11±4 s, p=0.9), while the peak enhancement time of the kidney tended to be a few seconds earlier (8±1 s, p=0.082 vs. pancreas and p=0.069 vs. kidney). Simulation showed that the time span in which the tissue enhancement remained within 10% of its peak value was similar across all capillary densities and ranged between 26-38 s for a capillary density of 80 per mm to 30-60 s for a capillary density of 10.The plateau tissue enhancement clinically acquired in the "late arterial phase" should be adequate both for the detection of hypervascular liver lesions such as HCCs and for obtaining peak pancreatic enhancement to detect hypovascular lesions. · The peak tissue enhancement time of an HCC, the pancreas, and the kidney cortex is similar. · The tissue peak enhancement time in the arterial phase is at the end of bolus transit. · Simulation shows that tissue enhancement peak time is a function of capillary density. · Cressoni M, Cadringher P, Colarieti A et al. Is there a need for a CT scan of the pancreatic phase? A perfusion and simulation study of the pancreas, an HCC, and the kidney cortex. Rofo 2025; 197: 1405-1415.

RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden VerfahrenVol. 197(12)
University of Milan (IT), IRCCS Policlinico San Donato (IT), University of Milano-Bicocca (IT)
Good health and well-being
Openalex Percentile: Top 13%
MRI in cancer diagnosis
2.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.