Microbial assessment and performance evaluation of eyewash stations in the laboratory setting

Eyewash stations are an essential component of laboratory safety programs, providing first aid in case of ocular exposure to hazardous materials. However, the presence of microbial contamination in these devices poses a potential risk of ocular infection to laboratory employees. This cross-sectional study aimed to evaluate the microbial quality and performance of 40 eyewash stations fixed in 10 buildings in a laboratory setting. Water quality parameters, including temperature, pH, turbidity, and the presence of <i>Acanthamoeba</i> spp., were measured at various time points (first draw, after 2 min of flushing, and 15 min flushing) from samples collected from each of the 40 eyewash stations. Performance and operational data were also measured according to the American National Standards Institute (ANSI)/International Safety Equipment Association (ISEA) Z358.1-2014 standard. Our results showed variable compliance with this standard across measures of physical condition, performance, access, and maintenance. Out of the 147 water samples collected (130 eyewash samples, 17 building reference samples), 28 samples were suspected to contain <i>Acanthamoeba</i> spp. or other free-living amoeba based on initial testing. Further analysis using polymerase chain reaction (PCR) confirmed the presence of <i>Acanthamoeba</i> spp. in 5 out of 28 samples. The results of this study provide insights into the potential risk of ocular infections associated with using eyewash stations and provide the basis for the recommendations on maintenance protocols to minimize the risk of microbial contamination.

Authors

Institutions

Publication Details

Journal
Journal of Occupational and Environmental Hygiene
Published
2025-02-06
DOI
https://doi.org/10.1080/15459624.2024.2443208
Primary Topic
Legionella and Acanthamoeba research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microbial assessment and performance evaluation of eyewash stations in the laboratory setting

Ibne Karim M. Ali, Derek Newcomer, Shantanu Roy, Jennifer R. Cope et al.
Journal of Occupational and Environmental Hygiene
Legionella and Acanthamoeba research
article

Microbial assessment and performance evaluation of eyewash stations in the laboratory setting

Ibne Karim M. Ali, Derek Newcomer, Shantanu Roy, Jennifer R. Cope, Ishveen Chopra, Judi Todd Darnell
article en

Abstract

Eyewash stations are an essential component of laboratory safety programs, providing first aid in case of ocular exposure to hazardous materials. However, the presence of microbial contamination in these devices poses a potential risk of ocular infection to laboratory employees. This cross-sectional study aimed to evaluate the microbial quality and performance of 40 eyewash stations fixed in 10 buildings in a laboratory setting. Water quality parameters, including temperature, pH, turbidity, and the presence of <i>Acanthamoeba</i> spp., were measured at various time points (first draw, after 2 min of flushing, and 15 min flushing) from samples collected from each of the 40 eyewash stations. Performance and operational data were also measured according to the American National Standards Institute (ANSI)/International Safety Equipment Association (ISEA) Z358.1-2014 standard. Our results showed variable compliance with this standard across measures of physical condition, performance, access, and maintenance. Out of the 147 water samples collected (130 eyewash samples, 17 building reference samples), 28 samples were suspected to contain <i>Acanthamoeba</i> spp. or other free-living amoeba based on initial testing. Further analysis using polymerase chain reaction (PCR) confirmed the presence of <i>Acanthamoeba</i> spp. in 5 out of 28 samples. The results of this study provide insights into the potential risk of ocular infections associated with using eyewash stations and provide the basis for the recommendations on maintenance protocols to minimize the risk of microbial contamination.

Journal of Occupational and Environmental HygieneVol. 22(4)
Centers for Disease Control and Prevention (US), National Institutes of Health (US), National Center for Emerging and Zoonotic Infectious Diseases (US), Office of Research Services (US)
Openalex Percentile: Top 98%
Legionella and Acanthamoeba research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.