Applying a quantitative fire risk assessment method in hospital settings: Case study

Understanding and mitigating fire risks in healthcare settings are crucial for ensuring the safety of individuals, especially during the current pandemic, which has increased the use of oxygen-supply equipment and potentially raised fire hazards. This case study, conducted in two university hospitals in Semnan, Iran, examined fire risk factors in healthcare facilities using a developed fire risk assessment method. A total of 28 wards and 74 compartments were assessed. Data collection included topographical structure analysis, building usage evaluation, and process documentation review. The FRAME method, validated in previous studies, was used to calculate fire risk levels for buildings, contents, occupants, and activities. The fire risk assessment revealed varying risk levels across different wards and compartments in the two hospitals. Hospital A exhibited higher fire risk levels compared to Hospital B, with several wards in Hospital A classified as "High" or "Very High" risk. Factors contributing to higher risk levels included building design, occupancy density, and the presence of flammable materials. Occupants in certain wards, particularly those with high occupancy rates and limited evacuation routes, were identified as being at increased risk. Activities such as the storage and handling of flammable materials were also found to contribute to elevated risk levels in specific areas. The study emphasizes the importance of implementing targeted fire safety measures, especially regarding oxygen-supplying equipment, high-density ventilators, and limited escape routes, to mitigate risks effectively in healthcare settings. This comprehensive assessment can guide best practices in fire safety management in hospitals.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2025-02-06
DOI
https://doi.org/10.1371/journal.pone.0315936
Primary Topic
Injury Epidemiology and Prevention
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Applying a quantitative fire risk assessment method in hospital settings: Case study

Marzieh Belji Kangarlou, Alireza Dehdashti, Ali Ghazvinloo, Mohammad Reza MirLavasani
PLoS ONE
Injury Epidemiology and Prevention
article

Applying a quantitative fire risk assessment method in hospital settings: Case study

Marzieh Belji Kangarlou, Alireza Dehdashti, Ali Ghazvinloo, Mohammad Reza MirLavasani
article en

Abstract

Understanding and mitigating fire risks in healthcare settings are crucial for ensuring the safety of individuals, especially during the current pandemic, which has increased the use of oxygen-supply equipment and potentially raised fire hazards. This case study, conducted in two university hospitals in Semnan, Iran, examined fire risk factors in healthcare facilities using a developed fire risk assessment method. A total of 28 wards and 74 compartments were assessed. Data collection included topographical structure analysis, building usage evaluation, and process documentation review. The FRAME method, validated in previous studies, was used to calculate fire risk levels for buildings, contents, occupants, and activities. The fire risk assessment revealed varying risk levels across different wards and compartments in the two hospitals. Hospital A exhibited higher fire risk levels compared to Hospital B, with several wards in Hospital A classified as "High" or "Very High" risk. Factors contributing to higher risk levels included building design, occupancy density, and the presence of flammable materials. Occupants in certain wards, particularly those with high occupancy rates and limited evacuation routes, were identified as being at increased risk. Activities such as the storage and handling of flammable materials were also found to contribute to elevated risk levels in specific areas. The study emphasizes the importance of implementing targeted fire safety measures, especially regarding oxygen-supplying equipment, high-density ventilators, and limited escape routes, to mitigate risks effectively in healthcare settings. This comprehensive assessment can guide best practices in fire safety management in hospitals.

PLoS ONEVol. 20(2)
Tarbiat Modares University (IR), Islamic Azad University Semnan (IR), Semnan University of Medical Sciences (IR)
Good health and well-being
Openalex Percentile: Top 97%
Injury Epidemiology and Prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Applying a quantitative fire risk assessment method in hospital settings: Case study — Marzieh Belji Kangarlou, Alireza Dehdashti, et al. · PLoS ONE (2025) | TGRS Research Map | TGRS