Design and Implementation of Active Distribution Network True Test Platform

In the context of the construction of new power systems, there is an urgent need for true testing and verification of new fault self-healing algorithms for active distribution networks with a large number of distributed photovoltaics connected in order to ensure their safe and reliable operation after being connected to the network. This paper proposes a real test platform for active distribution networks and establishes a 10kV distribution network real test environment consisting of a real primary system, a scene simulation system, a measurement and control system, and a test scene management system. The authenticity and practicality of the simulated environment of the active distribution network real test platform were verified through on-site single-phase grounding fault testing application.

Authors

Institutions

Publication Details

Published
2024-11-22
DOI
https://doi.org/10.1109/icdsca63855.2024.10859748
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Implementation of Active Distribution Network True Test Platform

Yongqing Zhu, Zhen Li, Julong Chen, Yu Zhang et al.
Power Systems and Technologies
article

Design and Implementation of Active Distribution Network True Test Platform

Yongqing Zhu, Zhen Li, Julong Chen, Yu Zhang, Qingsheng Li
article en

Abstract

In the context of the construction of new power systems, there is an urgent need for true testing and verification of new fault self-healing algorithms for active distribution networks with a large number of distributed photovoltaics connected in order to ensure their safe and reliable operation after being connected to the network. This paper proposes a real test platform for active distribution networks and establishes a 10kV distribution network real test environment consisting of a real primary system, a scene simulation system, a measurement and control system, and a test scene management system. The authenticity and practicality of the simulated environment of the active distribution network real test platform were verified through on-site single-phase grounding fault testing application.

Guizhou Electric Power Design and Research Institute (CN)
Industry, innovation and infrastructure
Openalex Percentile: Top 75%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.