Safety and Effectiveness of MiniMed <sup>TM</sup> 780G Advanced Hybrid Closed-Loop Insulin Intensification in Adults with Insulin-Requiring Type 2 Diabetes
<b><i>Background:</i></b> Early feasibility studies have demonstrated safe and effective automated insulin delivery use in individuals with suboptimally controlled type 2 diabetes (T2D). The present study investigated MiniMed™ 780G advanced hybrid closed-loop (AHCL) therapy safety and effectiveness in adults with insulin-requiring T2D. <b><i>Materials and Methods:</i></b> This 13-site, single-arm, open-label study included 95 adults (mean ± standard deviation [SD] age of 60.3 ± 10.8 years and T2D duration of 18.6 ± 8.6 years) using basal-bolus insulin therapy. Participants underwent a run-in period (∼21 days) of open-loop or HCL followed by a study period (∼90 days) of AHCL. The primary safety end point was mean change in glycosylated hemoglobin (HbA1c) from baseline to the end of the 3-month study period. The primary and secondary effectiveness end points were noninferiority and superiority in the percentage of time in range (%TIR 70-180 mg/dL) during the last 6 weeks of the study period (computed by the Hodges-Lehmann method). Safety metrics, including the rates of severe hypoglycemia, diabetic ketoacidosis (DKA), and hyperosmolar hyperglycemic state (HHS), were summarized. <b><i>Results:</i></b> HbA1c was reduced from 7.9% ± 1.0% (62.4 ± 10.4 mmol/mol) at baseline to 7.2 ± 0.7% (54.7 ± 8.0 mmol/mol) (<i>P</i> < 0.001). The %TIR estimate was 80.9% (95% confidence interval: 78.4%, 83.1%), and the significance criteria for both the primary and secondary effectiveness end points were met (<i>P</i> < 0.001). While total daily insulin dose was increased from run-in to the end of the study (77.4 ± 38.5 U vs. 91.8 ± 49.3 U, <i>P</i> < 0.0001), announced carbohydrates were unchanged, and the number of daily user-initiated boluses was reduced (3.9 ± 1.9 vs. 3.2 ± 1.8, <i>P</i> < 0.0001). There was no significant change in participant weight or body mass index, no severe hypoglycemia, DKA, or HHS, and no serious or unanticipated adverse device effects. <b><i>Conclusions:</i></b> These findings show that MiniMed 780G AHCL use provides safe insulin intensification in type 2 diabetes and significantly improves mean HbA1c and %TIR.
Authors
- Robert Alan Vigersky (ORCID: https://orcid.org/0000-0002-3546-3385)
- Bruce W. Bode (ORCID: https://orcid.org/0000-0002-9998-055X)
- Anders L. Carlson (ORCID: https://orcid.org/0000-0002-5738-2818)
- Mark Warren (ORCID: https://orcid.org/0000-0001-6693-9860)
- Andrew S. Rhinehart
- Anuj Bhargava (ORCID: https://orcid.org/0000-0002-5961-6171)
- Richard M. Bergenstal (ORCID: https://orcid.org/0000-0002-9050-5584)
- Ashleigh Keiter (ORCID: https://orcid.org/0000-0002-0125-7663)
- John Shin (ORCID: https://orcid.org/0000-0001-7831-8404)
- Toni L. Cordero (ORCID: https://orcid.org/0000-0003-4597-4194)
- Michael A. Dempsey
- James Thrasher
- JENNIFER J.F. MCVEAN (ORCID: https://orcid.org/0000-0001-8436-671X)
- Haoxi Ma
- James LaRocque
Institutions
- Chesapeake Public Schools (US)
- Medtronic (United States) (US)
- Arkansas Cardiology (US)
- Atlanta Diabetes Associates (US)
- Clinical Research Consultants (United States) (US)
- Iowa Diabetes and Endocrinology Research Center (US)
- Physicians East (US)
- HealthPartners (US)
Publication Details
- Journal
- Diabetes Technology & Therapeutics
- Published
- 2025-02-06
- DOI
- https://doi.org/10.1089/dia.2024.0586
- Citations
- 19
- Primary Topic
- Diabetes Management and Research
- Type
- article
- Field-Weighted Citation Impact
- 24.60