Evaluation of Glazing and Polishing for Novel Chairside CAD/CAM Lithium Disilicate Containing Virgilite Crystals

This comparative in vitro study evaluated surface treatment methods for chairside CAD/CAM lithium disilicate enriched with virgilite using atomic force microscopy (AFM) imaging. Specimens were fabricated from two lithium disilicate materials: the traditional material (IPS e.max CAD, Ivoclar Vivadent, Schaan, Liechtenstein) and a virgilite-containing material (CEREC Tessera, Dentsply Sirona, Charlotte, NC, USA). Surface roughness (Ra) [in micrometers (μm)] was quantitatively assessed with AFM. The results demonstrated that IPS e.max CAD with glazing exhibited the smoothest surface with the lowest Ra values (10.03 ± 5.03 μm). In contrast, CEREC Tessera exhibited the highest surface roughness when treated with glazing (51.98 ± 12.31 μm), while the zirconia polishing system provided a smoother surface (15.44 ± 9.69 μm).

Authors

Institutions

Publication Details

Journal
Operative Dentistry
Published
2025-02-06
DOI
https://doi.org/10.2341/23-165.1-l
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Glazing and Polishing for Novel Chairside CAD/CAM Lithium Disilicate Containing Virgilite Crystals

Nicholas G. Fischer, Carlos Alberto Jurado, Salahaldeen Abuhammoud, Silvia Rojas‐Rueda et al.
Operative Dentistry
Dental materials and restorations
article

Evaluation of Glazing and Polishing for Novel Chairside CAD/CAM Lithium Disilicate Containing Virgilite Crystals

Nicholas G. Fischer, Carlos Alberto Jurado, Salahaldeen Abuhammoud, Silvia Rojas‐Rueda, KI Afrashtehfar, FX Apiazu-Flores
article en

Abstract

This comparative in vitro study evaluated surface treatment methods for chairside CAD/CAM lithium disilicate enriched with virgilite using atomic force microscopy (AFM) imaging. Specimens were fabricated from two lithium disilicate materials: the traditional material (IPS e.max CAD, Ivoclar Vivadent, Schaan, Liechtenstein) and a virgilite-containing material (CEREC Tessera, Dentsply Sirona, Charlotte, NC, USA). Surface roughness (Ra) [in micrometers (μm)] was quantitatively assessed with AFM. The results demonstrated that IPS e.max CAD with glazing exhibited the smoothest surface with the lowest Ra values (10.03 ± 5.03 μm). In contrast, CEREC Tessera exhibited the highest surface roughness when treated with glazing (51.98 ± 12.31 μm), while the zirconia polishing system provided a smoother surface (15.44 ± 9.69 μm).

Operative DentistryVol. 50(2)
University of Bern (CH), University of Iowa (US), University of Minnesota (US), University of Tennessee Health Science Center (US), Ajman University (AE), University of Alabama at Birmingham (US), Indiana University – Purdue University Indianapolis (US)
Openalex Percentile: Top 98%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of Glazing and Polishing for Novel Chairside CAD/CAM Lithium Disilicate Containing Virgilite Crystals — Nicholas G. Fischer, Carlos Alberto Jurado, et al. · Operative Dentistry (2025) | TGRS Research Map | TGRS