Usefulness of Dorsal Scapular Artery Perforator Flap for Donor Site Closure After Harvesting Latissimus Dorsi Flap/Thoracodorsal Artery Perforator Flap: A Report of Three Cases

Reducing donor-site morbidity is crucial in free-flap reconstruction, with the primary goals of achieving dermis-to-dermis closure and avoiding skin grafts. Although latissimus dorsi (LD) myocutaneous and thoracodorsal artery perforator (TDAP) flaps usually allow primary closure, larger flap harvests may require skin grafts, potentially leading to undesirable outcomes. In such situations, local flap transfer can be considered for donor-site closure, yet there are few reports on this. This report aims to present cases where a dorsal scapular artery perforator (DSAP) rotational flap was used to close donor defects following large TDAP/LD flap harvests. The first case involved a 16-year-old girl who required a below-knee amputation due to an acute thrombotic event, leaving a 20 × 20 cm<sup>2</sup>-sized stump defect. Bilateral LD myocutaneous flaps were harvested, with the right donor site closed primarily, while a 20 × 9 cm<sup>2</sup>-sized defect remained on the left. A 22 × 9 cm<sup>2</sup>-sized DSAP flap, based on three perforators, was rotated to close the defect, showing excellent outcomes at 12 months. In the second and third cases, 75- and 78-year-old male patients with scalp angiosarcoma underwent wide excision and reconstruction with TDAP flaps, leaving 14 × 6 cm<sup>2</sup> and 14 × 7 cm<sup>2</sup>-sized donor defects. DSAP flaps, 15 × 7 cm<sup>2</sup> and 15 × 8 cm<sup>2</sup> in size, were rotated based on nearby perforators to close these areas. Both patients showed no morbidities at postoperative 8 and 2 months, respectively. When primary closure of the donor site is challenging after harvesting large TDAP /LD flaps, a DSAP rotational flap can provide a valuable option for minimizing donor-site morbidity.

Authors

Institutions

Publication Details

Journal
Microsurgery
Published
2025-02-01
DOI
https://doi.org/10.1002/micr.70033
Primary Topic
Reconstructive Surgery and Microvascular Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Usefulness of Dorsal Scapular Artery Perforator Flap for Donor Site Closure After Harvesting Latissimus Dorsi Flap/Thoracodorsal Artery Perforator Flap: A Report of Three Cases

Se Yeon Park, Kyeong‐Tae Lee
Microsurgery
Reconstructive Surgery and Microvascular Techniques
article

Usefulness of Dorsal Scapular Artery Perforator Flap for Donor Site Closure After Harvesting Latissimus Dorsi Flap/Thoracodorsal Artery Perforator Flap: A Report of Three Cases

Se Yeon Park, Kyeong‐Tae Lee
article en

Abstract

Reducing donor-site morbidity is crucial in free-flap reconstruction, with the primary goals of achieving dermis-to-dermis closure and avoiding skin grafts. Although latissimus dorsi (LD) myocutaneous and thoracodorsal artery perforator (TDAP) flaps usually allow primary closure, larger flap harvests may require skin grafts, potentially leading to undesirable outcomes. In such situations, local flap transfer can be considered for donor-site closure, yet there are few reports on this. This report aims to present cases where a dorsal scapular artery perforator (DSAP) rotational flap was used to close donor defects following large TDAP/LD flap harvests. The first case involved a 16-year-old girl who required a below-knee amputation due to an acute thrombotic event, leaving a 20 × 20 cm<sup>2</sup>-sized stump defect. Bilateral LD myocutaneous flaps were harvested, with the right donor site closed primarily, while a 20 × 9 cm<sup>2</sup>-sized defect remained on the left. A 22 × 9 cm<sup>2</sup>-sized DSAP flap, based on three perforators, was rotated to close the defect, showing excellent outcomes at 12 months. In the second and third cases, 75- and 78-year-old male patients with scalp angiosarcoma underwent wide excision and reconstruction with TDAP flaps, leaving 14 × 6 cm<sup>2</sup> and 14 × 7 cm<sup>2</sup>-sized donor defects. DSAP flaps, 15 × 7 cm<sup>2</sup> and 15 × 8 cm<sup>2</sup> in size, were rotated based on nearby perforators to close these areas. Both patients showed no morbidities at postoperative 8 and 2 months, respectively. When primary closure of the donor site is challenging after harvesting large TDAP /LD flaps, a DSAP rotational flap can provide a valuable option for minimizing donor-site morbidity.

MicrosurgeryVol. 45(2)
Samsung Medical Center (KR), Sungkyunkwan University (KR)
Good health and well-being
Openalex Percentile: Top 96%
Reconstructive Surgery and Microvascular Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Usefulness of Dorsal Scapular Artery Perforator Flap for Donor Site Closure After Harvesting Latissimus Dorsi Flap/Thoracodorsal Artery Perforator Flap: A Report of Three Cases — Se Yeon Park, Kyeong‐Tae Lee · Microsurgery (2025) | TGRS Research Map | TGRS