A Novel LC-MS/MS Method for the Measurement of Elexacaftor, Tezacaftor and Ivacaftor in Plasma, Dried Plasma Spot (DPS) and Whole Blood in Volumetric Absorptive Microsampling (VAMS) Devices

<b>Background:</b> The combination of ivacaftor, tezacaftor and elexacaftor (ETI) is approved for patients with cystic fibrosis (CF) aged two years and older and at least one F508del mutation in the CFTR gene. Variability in ETI treatment response has been repeatedly reported, and its reasons are unclear and understudied. <b>Objectives:</b> We present a novel liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the rapid and simultaneous quantification of ETI in plasma, dried plasma spots (DPS), and whole blood volumetric absorptive microsampling (VAMS). <b>Methods:</b> The method utilizes a rapid extraction protocol with 200 μL methanol after the addition of deuterated internal standards. Chromatographic separation was achieved using a reversed-phase Hypersil Gold aQ column (Thermo Fisher Scientific). The method was validated according to ICH (International Council on Harmonisation) guidelines M10 for bioanalytical method validation, demonstrating linearity in the concentration range 0.020-12.000 µg/mL. It was also proved accurate and reproducible with no matrix effect. This method was applied to anonymized samples from patients undergoing ETI treatment: eight plasma and DPS and five VAMS samples were analyzed. <b>Results:</b> ETI concentrations measured in plasma and DPS were interchangeable, whereas ETI concentrations in VAMS were lower than in plasma, as expected for molecules with high plasma protein binding (99%). A correction factor based on the hematocrit value was used to calculate the equivalent plasma concentration from VAMS concentrations. <b>Conclusions:</b> This method is suitable for pharmacokinetic (PK) studies and could facilitate the centralization of samples to specialized laboratories, supporting multicenter studies.

Authors

Institutions

Publication Details

Journal
Pharmaceutics
Published
2025-02-06
DOI
https://doi.org/10.3390/pharmaceutics17020200
Citations
5
Primary Topic
Cystic Fibrosis Research Advances
Type
article
Field-Weighted Citation Impact
7.59

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel LC-MS/MS Method for the Measurement of Elexacaftor, Tezacaftor and Ivacaftor in Plasma, Dried Plasma Spot (DPS) and Whole Blood in Volumetric Absorptive Microsampling (VAMS) Devices

Francesca Mattioli, Alessia Cafaro, Federico Cresta, Nicoletta Pedemonte et al.
5 citations
Pharmaceutics
Cystic Fibrosis Research Advances
7.59
article

A Novel LC-MS/MS Method for the Measurement of Elexacaftor, Tezacaftor and Ivacaftor in Plasma, Dried Plasma Spot (DPS) and Whole Blood in Volumetric Absorptive Microsampling (VAMS) Devices

Francesca Mattioli, Alessia Cafaro, Federico Cresta, Nicoletta Pedemonte, Giuliana Cangemi, Sebastiano Barco, Carlo Castellani, Federica Pigliasco, Rosaria Casciaro
article en
5 citations

Abstract

<b>Background:</b> The combination of ivacaftor, tezacaftor and elexacaftor (ETI) is approved for patients with cystic fibrosis (CF) aged two years and older and at least one F508del mutation in the CFTR gene. Variability in ETI treatment response has been repeatedly reported, and its reasons are unclear and understudied. <b>Objectives:</b> We present a novel liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the rapid and simultaneous quantification of ETI in plasma, dried plasma spots (DPS), and whole blood volumetric absorptive microsampling (VAMS). <b>Methods:</b> The method utilizes a rapid extraction protocol with 200 μL methanol after the addition of deuterated internal standards. Chromatographic separation was achieved using a reversed-phase Hypersil Gold aQ column (Thermo Fisher Scientific). The method was validated according to ICH (International Council on Harmonisation) guidelines M10 for bioanalytical method validation, demonstrating linearity in the concentration range 0.020-12.000 µg/mL. It was also proved accurate and reproducible with no matrix effect. This method was applied to anonymized samples from patients undergoing ETI treatment: eight plasma and DPS and five VAMS samples were analyzed. <b>Results:</b> ETI concentrations measured in plasma and DPS were interchangeable, whereas ETI concentrations in VAMS were lower than in plasma, as expected for molecules with high plasma protein binding (99%). A correction factor based on the hematocrit value was used to calculate the equivalent plasma concentration from VAMS concentrations. <b>Conclusions:</b> This method is suitable for pharmacokinetic (PK) studies and could facilitate the centralization of samples to specialized laboratories, supporting multicenter studies.

PharmaceuticsVol. 17(2)
Istituto Giannina Gaslini (IT), Ente Ospedaliero Ospedali Galliera (IT), Istituti di Ricovero e Cura a Carattere Scientifico (IT), University of Genoa (IT)
Ministero della Salute
Openalex Percentile: Top 3%
Cystic Fibrosis Research Advances
7.59
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.