In-situ estimation of gamma-ray source location at a specific depth based on a coded-aperture gamma camera

The coded-aperture gamma imager, EPSILON-G, was employed to swiftly identify gamma-ray sources in-situ. EPSILON-G is a device that gathers data using a detector module that integrates a GAGG(Ce) scintillator with a SiPM array and accurately locates gamma-ray sources through image reconstruction. To confirm its imaging capability and performance in-situ, the minimum count rate for imaging (MCI) was determined using MCNPX-PoliMi code simulations. Using the MCI, the minimum detectable activity (MDA) was calculated as representing the concentration at which surface radioactivity can be feasibly reconstructed in-situ. Additionally, a depth estimation method utilizing dual image acquisition was developed to identify radioactive materials at specific surface depths during radiological emergencies. This depth estimation method was theoretically proposed and validated through experiments with a 137 Cs gamma-ray source. The MDA satisfying the MCI for soil standards was 3.663 Bq/g. In-situ depth estimation experiments using a sandbox enabled the depth to be estimated up to 24.9 ± 2.3 cm with the 137 Cs (3.5 MBq) source.

Authors

Institutions

Publication Details

Journal
Nuclear Engineering and Technology
Published
2025-02-06
DOI
https://doi.org/10.1016/j.net.2025.103483
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In-situ estimation of gamma-ray source location at a specific depth based on a coded-aperture gamma camera

Manhee Jeong, D. S. Kim
Nuclear Engineering and Technology
Radiation Detection and Scintillator Technologies
article

In-situ estimation of gamma-ray source location at a specific depth based on a coded-aperture gamma camera

Manhee Jeong, D. S. Kim
article en

Abstract

The coded-aperture gamma imager, EPSILON-G, was employed to swiftly identify gamma-ray sources in-situ. EPSILON-G is a device that gathers data using a detector module that integrates a GAGG(Ce) scintillator with a SiPM array and accurately locates gamma-ray sources through image reconstruction. To confirm its imaging capability and performance in-situ, the minimum count rate for imaging (MCI) was determined using MCNPX-PoliMi code simulations. Using the MCI, the minimum detectable activity (MDA) was calculated as representing the concentration at which surface radioactivity can be feasibly reconstructed in-situ. Additionally, a depth estimation method utilizing dual image acquisition was developed to identify radioactive materials at specific surface depths during radiological emergencies. This depth estimation method was theoretically proposed and validated through experiments with a 137 Cs gamma-ray source. The MDA satisfying the MCI for soil standards was 3.663 Bq/g. In-situ depth estimation experiments using a sandbox enabled the depth to be estimated up to 24.9 ± 2.3 cm with the 137 Cs (3.5 MBq) source.

Nuclear Engineering and TechnologyVol. 57(7)
Jeju National University (KR)
Nuclear Safety and Security Commission
Openalex Percentile: Top 97%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.