miRNA Library Preparation Optimisation for Low-Concentration and Low-Volume Paediatric Plasma Samples

<b>Background:</b> Analysing circulating miRNAs in paediatric plasma is challenging due to typically low sample volumes. The QIAseq miRNA UDI Library Kit (Qiagen, Hilden, Germany) was selected as it has a proven track record with a specific protocol for plasma and serum. The protocol, however, required optimisation for use with low-volume paediatric plasma samples before generating acceptable yields in our cohort. <b>Methods:</b> The miRNeasy Serum/Plasma kit (Qiagen) and the MagMAX miRVana Total Isolation kit (ThermoFisher Scientific, Waltham, MA, USA) were assessed following the manufacturer's instructions with 100 µL and 200 µL of paediatric plasma. Libraries were prepared using the QIAseq miRNA UDI Library Kit (Qiagen). Optimisations were made for the QIAseq miRNA UDI Library Kit (Qiagen) using total RNA extracted with the miRNeasy Serum/Plasma kit (Qiagen) from 100 µL of plasma. <b>Results:</b> Prior to optimisation, both RNA extraction kits underperformed with the QIAseq miRNA UDI Library kit, producing low miRNA library yields ranging between 0 and 1.42 ng/µL. Plasma input volumes of 100 µL and 200 µL demonstrated no significant differences. Adjusting the QIAseq protocol for low RNA concentrations improved miRNA library yields, an average of 5.6 ng/µL and a maximum of 24.3 ng/µL across 92 samples. The optimised protocol showed no age or gender biases with the QIAseq kit. <b>Conclusions:</b> Failure rates in miRNA library preparations are rarely reported, making it hard to gauge whether the 8.7% failure rate observed here is typical. However, given the challenges of using low-concentration, low-volume paediatric plasma, this represents a significant improvement over previous attempts, supporting further research in the field.

Authors

Institutions

Publication Details

Journal
Non-Coding RNA
Published
2025-02-05
DOI
https://doi.org/10.3390/ncrna11010011
Citations
5
Primary Topic
MicroRNA in disease regulation
Type
article
Field-Weighted Citation Impact
4.68

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

miRNA Library Preparation Optimisation for Low-Concentration and Low-Volume Paediatric Plasma Samples

Oenone Rodgers, Thomas Waterfield, Chris Watson
5 citations
Non-Coding RNA
MicroRNA in disease regulation
4.68
article

miRNA Library Preparation Optimisation for Low-Concentration and Low-Volume Paediatric Plasma Samples

Oenone Rodgers, Thomas Waterfield, Chris Watson
article en
5 citations

Abstract

<b>Background:</b> Analysing circulating miRNAs in paediatric plasma is challenging due to typically low sample volumes. The QIAseq miRNA UDI Library Kit (Qiagen, Hilden, Germany) was selected as it has a proven track record with a specific protocol for plasma and serum. The protocol, however, required optimisation for use with low-volume paediatric plasma samples before generating acceptable yields in our cohort. <b>Methods:</b> The miRNeasy Serum/Plasma kit (Qiagen) and the MagMAX miRVana Total Isolation kit (ThermoFisher Scientific, Waltham, MA, USA) were assessed following the manufacturer's instructions with 100 µL and 200 µL of paediatric plasma. Libraries were prepared using the QIAseq miRNA UDI Library Kit (Qiagen). Optimisations were made for the QIAseq miRNA UDI Library Kit (Qiagen) using total RNA extracted with the miRNeasy Serum/Plasma kit (Qiagen) from 100 µL of plasma. <b>Results:</b> Prior to optimisation, both RNA extraction kits underperformed with the QIAseq miRNA UDI Library kit, producing low miRNA library yields ranging between 0 and 1.42 ng/µL. Plasma input volumes of 100 µL and 200 µL demonstrated no significant differences. Adjusting the QIAseq protocol for low RNA concentrations improved miRNA library yields, an average of 5.6 ng/µL and a maximum of 24.3 ng/µL across 92 samples. The optimised protocol showed no age or gender biases with the QIAseq kit. <b>Conclusions:</b> Failure rates in miRNA library preparations are rarely reported, making it hard to gauge whether the 8.7% failure rate observed here is typical. However, given the challenges of using low-concentration, low-volume paediatric plasma, this represents a significant improvement over previous attempts, supporting further research in the field.

Non-Coding RNAVol. 11(1)
Queen's University Belfast (GB)
Department for the Economy, Queen's University Belfast, Queen's University, Northern Ireland Chest Heart and Stroke
Openalex Percentile: Top 6%
MicroRNA in disease regulation
4.68
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.