Combined Correction of Coronal and Rotational Deformities of the Femur With Distal Femoral Osteotomy Using Patient-Specific Instrumentation
Coronal and rotational deformities of the femur can accurately be corrected simultaneously by a DFO, utilizing PSIs. High accuracy was achieved for the correction of both coronal and rotational deformities, with absolute mean differences from planned to achieved correction of 1.1° and 2.4°, respectively.
Authors
- Lukas Jud (ORCID: https://orcid.org/0000-0001-8128-3927)
- Sandro F. Fucentese (ORCID: https://orcid.org/0000-0003-2993-7537)
- Georgios Neopoulos (ORCID: https://orcid.org/0000-0002-1928-5021)
- Lazaros Vlachopoulos (ORCID: https://orcid.org/0009-0003-0178-8389)
Institutions
- University of Zurich (CH)
- Universitätsklinik Balgrist (CH)
Publication Details
- Journal
- The American Journal of Sports Medicine
- Published
- 2025-02-05
- DOI
- https://doi.org/10.1177/03635465251314868
- Citations
- 3
- Primary Topic
- Hip disorders and treatments
- Type
- article
- Field-Weighted Citation Impact
- 6.02